Suscribirse

Minimally invasive radio-guided surgery for primary hyperparathyroidism: From preoperative to intraoperative localization imaging - 21/12/10

Doi : 10.1016/j.ando.2010.08.001 
D. Rubello a, , N. Kapse b, G. Grassetto a, A. Massaro a, A. Al-Nahhas b
a Department of Nuclear Medicine, Medical Physics, Radiology, the Nuclear Medicine Service, PET/CT Centre, Santa Maria della Misericordia Hospital, viale Tre Martiri 140, 45100 Rovigo, Italy 
b Department of Nuclear Medicine, Hammersmith Hospital, London, United Kingdom 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Résumé

L’apparition et les progrès successifs de la parathyroïdectomie radioguidée mini-invasive (MIRP) ont révolutionné l’approche chirurgicale des adénomes parathyroïdiens. Le prérequis du succès est une localisation précise de la lésion en cause et dans ce but, une approche multimodale est couramment employée, associant imagerie anatomique et fonctionnelle. De toutes les techniques anatomiques, l’échographie est la plus largement disponible mais demeure opérateur-dépendant et a une sensibilité réduite, spécialement en cas de nodules thyroïdiens. De même, la tomodensitométrie et l’imagerie par résonance magnétique nucléaire ont une sensibilité basse, tout en apportant des informations particulièrement intéressantes dans la détection des adénomes rétrotrachéaux, rétro-œsophagiens et médiastinaux. L’imagerie fonctionnelle par scintigraphie au Technetium-Sestamibi est actuellement l’examen le plus employé en sachant qu’il existe divers protocoles incluant une image en double contraste et un double isotope. La sensibilité et la spécificité sont améliorées par l’acquisition en tomographie par émission de photons simples (SPECT) et l’utilisation d’un scanner couplé avec un faible rayonnement pour fournir des images anatomiques (SPECT/CT). L’attitude actuellement recommandée est une combinaison d’imagerie fonctionnelle avec la scintigraphie au Technetium-Sestami et d’échographie de haute résolution complétée par une étude en sonde gamma peropératoire dans certains cas associée à la mesure rapide de la parathormone également peropératoire. Cette revue a pour but d’évaluer l’utilité des différentes modalités d’imagerie seules ou en combinaison dans l’exploration des adénomes parathyroïdiens et de faciliter une approche de parathyroïdectomie mini-invasive.

El texto completo de este artículo está disponible en PDF.

Abstract

The introduction and successful implementation of minimally invasive radio-guided parathyroidectomy (MIRP) has revolutionized the surgical approach to remove parathyroid adenomas. A prerequisite for such success is an accurate localization of the offending adenoma. To achieve this goal, a multimodality approach is commonly employed using a combination of anatomical and functional imaging. Of the anatomical cross-sectional techniques, ultrasonography is the most widely available but is operator-dependent and has reduced sensitivity, specially in the presence of thyroid nodules. Similarly, computed tomography and magnetic resonance imaging have low sensitivities but provide value in detecting retrotracheal, retro-oesophageal and mediastinal adenomas. Functional imaging with 99mTc-Sestamibi is currently the most vital imaging procedure in this respect with variable protocols including dual-phase and dual isotope imaging. The sensitivity and specificity can improve by acquiring in single photon emission tomography (SPECT) mode and using co-registration with low dose CT to provide anatomical data (SPECT/CT). The current recommended approach is the combination of functional imaging with 99mTc-Sestamibi and high-resolution ultrasound (US), supplemented with intraoperative gamma probe in certain cases and quick persurgical measurement of parathyroid hormone. This review aims to explore the utility of various imaging modalities, alone and in combination, in detecting parathyroid adenoma and facilitating the current approach of MIRP.

El texto completo de este artículo está disponible en PDF.

Mots clés : Adénome parathyroïdien, Parathyroïdectomie mini-invasive, Scintigraphie au Sestamibi 99mTc, Imagerie bidimensionnelle

Keywords : Parathyroid adenoma, Minimally invasive parathyroidectomy, 99mTc-Sestamibi, Cross-sectional imaging


Esquema


© 2010  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 71 - N° 6

P. 511-518 - décembre 2010 Regresar al número
Artículo precedente Artículo precedente
  • Treatment of type 2 diabetes: New clinical studies and effects of GLP-1 on macrovascular complications
  • S. Lesven, J.-F. Gautier, R. Maréchaud
| Artículo siguiente Artículo siguiente
  • Thyroid function at the third trimester of pregnancy in a Northern French population
  • N. Bourcigaux, C. Lepoutre-Lussey, J. Guéchot, B. Donadille, I. Faugeron, S. Ouzounian, S. Christin-Maître, P. Bouchard, F. Duron

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.