Suscribirse

Multidetector Computed Tomography for the Diagnosis of Coronary Artery Disease: A Systematic Review - 18/08/11

Doi : 10.1016/j.amjmed.2005.06.071 
Paul D. Stein, MD a, b, , Afzal Beemath, MD a, Fadi Kayali, MD a, Elias Skaf, MD a, Julia Sanchez, MD a, Ronald E. Olson, PhD c
a Department of Research, St. Joseph Mercy Oakland Hospital, Pontiac, Mich. 
b Department of Internal Medicine, Wayne State University, Detroit, Mich. 
c Office of Grants, Contracts and Sponsored Research, Oakland University, Rochester, Mich. 

Requests for reprints should be addressed to Paul D. Stein, MD, Saint Joseph Mercy Oakland, 44405 Woodward Avenue, Pontiac, MI 48341-2985.

Abstract

Purpose

The study’s purpose was to determine the sensitivity and specificity of contrast-enhanced multidetector computed tomography (CT) for the detection of coronary artery disease.

Subjects and methods

A search of the literature in all languages was performed incorporating both electronic and manual components. Manual reference checks of recent reviews and all original investigations supplemented the electronic searches.

Results

Average sensitivity for patient-based detection of significant (>50% or ≥50%) stenosis was 61 of 64 (95%) with 4-slice CT, 276 of 292 (95%) with 16-slice CT, and 47 of 47 (100%) with 64-slice CT. Average specificity was 84% for 4-slice CT, 84% for 16-slice CT, and 100% for 64-slice CT. The sensitivity for a significant stenosis in evaluable segments was 307 of 372 (83%) with 4-slice CT, 1023 of 1160 (88%) with 16-slice CT, and 165 of 176 (94%) with 64-slice CT. Average specificity was 93% or greater with all multidetector CT. Seventy-eight percent of segments were evaluable with 4-slice CT, 91% with 16-slice CT, and 100% with 64-slice CT. Stenoses in proximal and mid-segments were shown with a higher sensitivity than distal segments. Left main stenosis was identified with high sensitivity with all multidetector CT, but sensitivity in other vessels increased with an increasing number of detectors.

Conclusion

Multidetector CT has the potential to be used as a screening test in appropriate patients. Contrast-enhanced 16-slice CT seems to be reasonably sensitive and specific for the detection of significant coronary artery disease but has shortcomings. Preliminary data with 64-slice CT suggest that it is more sensitive and specific.

El texto completo de este artículo está disponible en PDF.

Keywords : Coronary artery disease, Coronary angiography, Computed tomography


Esquema


© 2006  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 119 - N° 3

P. 203-216 - mars 2006 Regresar al número
Artículo precedente Artículo precedente
  • Aspirin to Prevent Heart Attack and Stroke: What’s the Right Dose?
  • James E. Dalen
| Artículo siguiente Artículo siguiente
  • Smoking Increases the Treatment Failure for Helicobacter pylori Eradication
  • Takeshi Suzuki, Keitaro Matsuo, Hidemi Ito, Akira Sawaki, Kaoru Hirose, Kenji Wakai, Shigeki Sato, Tsuneya Nakamura, Kenji Yamao, Ryuzo Ueda, Kazuo Tajima

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.