Purpose

To test the hypothesis that cataract extraction in glaucomatous eyes improves overall sensitivity of visual function without affecting the size or depth of glaucomatous scotomas.

Design

Experimental study with no control group.

Methods

One hundred fifty-eight eyes (of 140 patients) from the Advanced Glaucoma Intervention Study with at least two reliable visual fields within a year both before and after cataract surgery were included. Average mean deviation (MD), pattern standard deviation (PSD), and corrected pattern standard deviation (CPSD) were compared before and after cataract extraction. To evaluate changes in scotoma size, the number of abnormal points (P < .05) on the pattern deviation plot was compared before and after surgery. We described an index (“scotoma depth index”) to investigate changes of scotoma depth after surgery.

Results

Mean values for MD, PSD, and CPSD were –13.2, 6.4, and 5.9 dB before and –11.9, 6.8, and 6.2 dB after cataract surgery (P ≤ .001 for all comparisons). Mean (± SD) number of abnormal points on pattern deviation plot was 26.7 ± 9.4 and 27.5 ± 9.0 before and after cataract surgery, respectively (P = .02). Scotoma depth index did not change after cataract extraction (–19.3 vs –19.2 dB, P = .90).

Conclusions

Cataract extraction caused generalized improvement of the visual field, which was most marked in eyes with less advanced glaucomatous damage. Although the enlargement of scotomas was statistically significant, it was not clinically meaningful. No improvement of sensitivity was observed in the deepest part of the scotomas.

El texto completo de este artículo está disponible en PDF.

Esquema


 Supported by an unrestricted grant from Research to Prevent Blindness and National Institute of Health grant R01 EY12738.


© 2004  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 138 - N° 6

P. 1022-1028 - décembre 2004 Regresar al número
Artículo precedente Artículo precedente
  • Variable phenotype related to a novel PAX 6 mutation (IVS4+5G>C) in a family presenting congenital nystagmus and foveal hypoplasia
  • Marie-Claire Vincent, Raffaella Gallai, David Olivier, Claude Speeg-Schatz, Jacques Flament, Patrick Calvas, HélÈne Dollfus
| Artículo siguiente Artículo siguiente
  • Patterns of glaucomatous visual field progression identified by three progression criteria
  • Catherine Boden, Eytan Z. Blumenthal, John Pascual, Gavin McEwan, Robert N. Weinreb, Felipe Medeiros, Pamela A. Sample

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.