Suscribirse

3-T contrast-enhanced MR angiography with parallel imaging in cerebral venous and sinus thrombosis - 29/11/11

Doi : 10.1016/j.neurad.2011.01.002 
M. Lettau a, b, , M. Laible c, R.J. Barrows c, S. Heiland a, M. Bendszus a, S. Hähnel a
a Division of Neuroradiology, Department of Neurology, University of Heidelberg Medical Center, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany 
b Division of Neuroradiology, Department of Neurosurgery, University of Freiburg Medical Center, Breisacher Street 64, 79106 Freiburg, Germany 
c Department of Neurology, University of Heidelberg Medical Center, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany 

Corresponding author. Tel.: +761 270 5171; fax: +761 270 5114.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Background and purpose

Contrast-enhanced (CE) 3D magnetic resonance venography (MRV) and CE 3D magnetization prepared rapid acquisition of gradient echo (MP-RAGE) sequences are increasingly commonly used methods for evaluation of the intracranial venous system. Our aim was to compare CE MRV, 2D time-of-flight (TOF) MRV and MP-RAGE sequences at 3 T for visualization of cerebral venous and sinus thrombosis.

Material and methods

Patients with suspected or known cerebral venous thrombosis were examined prospectively by TOF MRV, CE MRV and MP-RAGE sequences. In 11 consecutive patients (all women; mean age, 42.5 years; age range, 25–70 years) with venous thrombosis, scores according to overall image quality, and presence or absence (score P) and differentiation (score D) of venous thrombosis were evaluated.

Results

By all measurements, overall image quality ranged from good to excellent. In 20 of 52 venous structures (38.5%), score P was the same on TOF MRV, CE MRV and MP-RAGE sequences. Venous thrombosis was definitely or almost definitely present or absent with TOF MRV in 20 of 52 (38.5%), with CE MRV in 97 of 99 (97.9%) and with MP-RAGE sequences in 86 of 99 (86.9%) venous structures. In all venous structures with uncertain diagnosis on TOF MRV, thrombosis was definitely or almost definitely present or absent on CE MRV and MP-RAGE sequences. Differentiation of thrombosis was better on CE MRV (score D: 3.33) than on MP-RAGE sequences (score D: 2.78), followed by TOF MRV (score D: 1.32).

Conclusion

CE MRV was superior to TOF MRV and MP-RAGE sequences in visualizing cerebral venous and sinus thrombosis.

El texto completo de este artículo está disponible en PDF.

Keywords : 3-T, Contrast-enhanced MR venography, MP-RAGE sequences, TOF MR venography, Parallel imaging, Cerebral venous and sinus thrombosis


Esquema


© 2011  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 38 - N° 5

P. 275-282 - décembre 2011 Regresar al número
Artículo precedente Artículo precedente
  • High-resolution 3T MR neurography of radial neuropathy
  • Neda Faridian-Aragh, Majid Chalian, Theodoros Soldatos, Gaurav K. Thawait, E. Gene Deune, Allan J. Belzberg, John A. Carrino, Avneesh Chhabra
| Artículo siguiente Artículo siguiente
  • Endovascular treatment of complex cerebral aneurysms with onyx hd-500® in 38 patients
  • J. Tevah, R. Senf, J. Cruz, M. Fava

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.