Suscribirse

De-escalation exchange of loosened locked revision stems to a primary stem design: Complications, stem fixation and bone reconstruction in 15 cases - 27/03/12

Doi : 10.1016/j.otsr.2011.08.016 
B. Miletic a, b, , O. May c, N. Krantz a, b, J. Girard a, b, G. Pasquier a, b, H. Migaud a, b
a Lille North of France University, 59000 Lille, France 
b D Department of Orthopaedic Surgery, Salengro Hospital, Lille Regional Teaching Hospital Center, place de Verdun, 59037 Lille cedex, France 
c Médipôle Garonne, 45, rue de Gironis, 31300 Toulouse, France 

Corresponding author. Tel.: +33 3 20 44 68 28; fax: +33 3 20 44 66 07.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Femoral stem revision with a locked stem after total hip arthroplasties treats severe bone defects by favoring spontaneous bone reconstruction. Initially, once reconstruction was obtained, the temporary implant was to be replaced by a standard primary component. The use of locked stems has increased, but repeat revision with a short stem which is also called “de-escalation” has not been extensively studied.

Hypothesis

Repeat revision of a locked stem with a short stem is not associated with any specific morbidity and does not affect the quality of reconstruction obtained, or fixation of the subsequent standard length primary design stem.

Patients and methods

Fifteen patients whose locked femoral stem was exchanged due to thigh pain and/or radiographic images showing failed osteointegration were analyzed. These 15 patients were all followed-up and evaluated by the Postel Merle d’Aubigné score. Progression of bone defects was evaluated using the Hofmann cortical index.

Results

There were no difficulties extracting the locked stem and a standard length primary stem was inserted with no associated procedures or bone complications in any of the cases. At a mean follow-up of 55months (36–84months), thigh pain had disappeared and the Postel Merle d’Aubigné score had increased from 12.6±2.9 (7–16) to 16.5±0.9 (15–18) (P=0.0001). The use of a locked femoral stem resulted in bone reconstruction in all cases, the Hofmann index increased from 30.5%±17.9% (12–71%) before insertion of the locked stem to 43.6%±25.6% (19–90%) at exchange (P<0.05). Bone reconstruction was durable after the exchange with a stable Hofmann index 43.7%±26.2% (17–92%) at the final follow-up (P=0.9). No recurrent loosening occurred.

Discussion

Revision of a loosened locked femoral stem with a standard design primary stem does not result in any specific increased morbidity, or modify bone reconstruction obtained with the locked stem and results in stable fixation of a new standard length stem.

Level of evidence

: IV: retrospective or historical series.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasty revision, Femoral bone loss, Locked femoral component


Esquema


© 2012  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 98 - N° 2

P. 138-143 - avril 2012 Regresar al número
Artículo precedente Artículo precedente
  • Acetabular reconstruction using morselized allograft and a reinforcement ring for revision arthroplasty with Paprosky type II and III bone loss: Survival analysis of 95 hips after 5 to 13 years
  • R. Philippe, O. Gosselin, J. Sedaghatian, C. Dezaly, O. Roche, F. Sirveaux, D. Molé
| Artículo siguiente Artículo siguiente
  • Infected total hip arthroplasty revision: One- or two-stage procedure?
  • S. Klouche, P. Leonard, V. Zeller, L. Lhotellier, W. Graff, P. Leclerc, P. Mamoudy, E. Sariali

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.