Reproducibility and influence of hand rotation on computer-aided joint space analysis - 30/06/12

Doi : 10.1016/j.jbspin.2011.07.011 
Alexander Pfeil a, , Andreas Hansch b, Julia Sommerfeld b, Rosemarie Fröber c, Diane M. Renz d, Gabriele Lehmann a, Ansgar Malich e, Gunter Wolf a, Joachim Böttcher f
a Department of Internal Medicine III, Friedrich-Schiller-University Jena, Erlanger Allee 101, 07747 Jena, Germany 
b Institute of Diagnostic and Interventional Radiology, Friedrich-Schiller-University Jena, Erlanger Allee 101, 07747 Jena, Germany 
c Institute of Anatomy I, Friedrich-Schiller-University Jena, Löbdergraben, Teichgraben 7, 07740 Jena, Germany 
d Department of Radiology, Charité University Medicine Berlin, Campus Virchow Clinic, Augustenburger Platz 1, 13353 Berlin, Germany 
e Department of Radiology, Suedharz Clinic Nordhausen, Dr Robert-Koch Street 39, 99734 Nordhausen, Germany 
f Institute of Diagnostic and Interventional Radiology, SRH Wald-Klinikum Gera, Straße des Friedens 122, 07548 Gera, Germany 

Corresponding author. Tel.: +49 3641 9324384; fax: +49-3641-9324302.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 5
Iconografías 2
Vídeos 0
Otros 0

Abstract

Objectives

Computer-aided joint space analysis (CAJSA) is a recently developed, semi-automated tool to aid in the measurement of joint space margins based on hand radiographs. The objective of this study is to verify the potential effect of hand rotation during X-ray imaging on the measurement of joint space width using CAJSA and to evaluate the reproducibility of the CAJSA technique in healthy subjects and in patients with rheumatoid arthritis.

Methods

All joint space distance (JSD) measurements were performed using CAJSA-technology at the metacarpophalangeal articulation based on conventional and digital hand radiographs.

Results

I. Hand rotation showed an effect on the reproducibility with CV ranging between 0.39% (angulation 1°) and 1.66% (angulation 19°). II. Regarding the overall reproducibility of the CAJSA method, the intra-radiograph reproducibility of JSD was calculated with CV=0.54% for conventional images and CV=0.38% for digital images. The inter-radiograph reproducibility error was observed with CV=0.66% (conventional images) and CV=0.63% (digital images). III. The study revealed a reproducibility for CAJSA measurements in RA ranging between 0.37% (JSD-MCP ring finger; van der Heijde-modification of the Sharp method Score 1) to 1.37% (JSD-MCP index finger; van der Heijde-modification of the Sharp method Score 3).

Conclusion

CAJSA measures JSD at the metacarpophalangeal articulation with high reproducibility in healthy subjects and in patients with differing stages of rheumatoid arthritis. Additional findings show that hand rotation during X-ray imaging has an impact on the CAJSA measurements; thus avoiding acquisition of hand radiographs with a rotation error of more than 15 degrees can be recommended.

El texto completo de este artículo está disponible en PDF.

Keywords : Rheumatoid arthritis, Computer-aided diagnosis, Computer-aided joint space analysis, Joint space width, X-ray imaging, Reproducibility


Esquema


© 2011  Société française de rhumatologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 79 - N° 4

P. 384-388 - juillet 2012 Regresar al número
Artículo precedente Artículo precedente
  • Assessment of hand trabecular bone texture with high resolution direct digital radiograph in rheumatoid arthritis: A case control study
  • Anne Fouque-Aubert, Stéphanie Boutroy, Hubert Marotte, Nicolas Vilayphiou, Eric Lespessailles, Claude-Laurent Benhamou, Pierre Miossec, Roland Chapurlat
| Artículo siguiente Artículo siguiente
  • Monitoring of bone turnover markers does not improve persistence with ibandronate treatment
  • Christian Roux, Bruno Giraudeau, Stéphanie Rouanet, Geneviève Dubourg, Elodie Perrodeau, Philippe Ravaud

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.