Suscribirse

Improving cardiac function with new-generation plasma volume expanders - 08/12/12

Doi : 10.1016/j.ajem.2012.05.031 
Surapong Chatpun a, b, Parimala Nacharaju c, Pedro Cabrales, PhD a,
a Department of Bioengineering, University of California–San Diego, La Jolla, CA 92093, USA 
b Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Songkhla, 90110, Thailand 
c Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY 10461, USA 

Corresponding author. Tel.: +1 858 534 8197.

Abstract

Background

Plasma expander (PE) based on polyethylene glycol (PEG) conjugated to albumin has shown positive results maintaining blood volume during hemodilution and restoring blood volume during resuscitation from hemorrhagic shock. Polyethylene glycol conjugation to human serum albumin (HSA), PEG-HSA, increases size, weight, and colloidal osmotic pressure, with minor effects on solution viscosity.

Methods

This study was designed to test the hypothesis that PEG-HSA (2 g/dL) produced by direct PEGylation chemistry improves cardiac function during 2 experimental models, (i) moderate hemodilution and (ii) resuscitation from hemorrhagic shock, compared with a conventional colloidal PE (Dextran 70 kd [Dx70], 6 g/dL). Cardiac function was studied using a miniaturized pressure volume conductance catheter implanted in the left ventricle and evaluated in terms of cardiac indices derived from the pressure volume measurements.

Results

Polyethylene glycol–HSA increased cardiac output, stroke volume, and stroke work and decreased systemic vascular resistance compared with Dx70 in both experimental models. The improvements induced by PEG-HSA in cardiac function were sustained over the observation time. Polyethylene glycol–HSA cardiac mechanoenergetics changes are the result of increased energy transferred per stroke and decreased resistance of the vasculature connecting the heart. In summary, PEG-HSA decreased left ventricle ejection impedance.

Conclusion

Ejection of blood diluted with PEG-HSA presented a reduced load to the heart, increased contractile function, and lowered the energy consumed per unit volume compared with Dx70. Our results emphasize the importance of heart function as a parameter to be included in the evaluation changes induced by new PEs.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2013  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 31 - N° 1

P. 54-63 - janvier 2013 Regresar al número
Artículo precedente Artículo precedente
  • Brain computed tomographic scan findings in acute opium overdose patients
  • Farkhondeh Jamshidi, Babak Sadighi, Kamran Aghakhani, Hossein Sanaei-Zadeh, Mohammadali Emamhadi, Nasim Zamani
| Artículo siguiente Artículo siguiente
  • End-tidal carbon dioxide is associated with mortality and lactate in patients with suspected sepsis
  • Christopher L. Hunter, Salvatore Silvestri, Matthew Dean, Jay L. Falk, Linda Papa

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.