CT scan does not improve the reproducibility of trochanteric fracture classification: A prospective observational study of 53 cases - 02/02/13

Doi : 10.1016/j.otsr.2012.09.019 
E. Cavaignac a, , M. Lecoq a, A. Ponsot b, A. Moine a, N. Bonnevialle a, P. Mansat a, N. Sans b, P. Bonnevialle a
a Musculoskeletal Institute at Toulouse, Teaching Hospital Center, Purpan Orthopaedics and Trauma Unit, place Baylac, 31052 Toulouse, France 
b Central Radiology Department at Purpan, Teaching Hospital Center, place Baylac, 31052 Toulouse, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

The reproducibility of various classification systems for trochanteric fractures is poor. This problem could be related to a lack of readability when using conventional X-rays.

Hypothesis

Computed tomography scanning (CT scan) will improve the interobserver reproducibility of the AO classification for trochanteric fractures.

Patients and methods

This was a prospective, observational, descriptive study following a group of 53 patients with trochanteric fractures. The fractures were evaluated with conventional X-rays, CT scan slices and 3D reconstruction (3DR). The resulting images were blinded and analysed by two observers using two classification systems: AO and Evans modified by Jensen (EVJE). A sample size of 53 was needed to show an improvement in the interobserver reproducibility when deciding the AO classification type with CT scan images. Kappa coefficients were used to measure interobserver reproducibility and agreement; agreement is the degree of consistency in the analysis by one observer who views the same fracture on two different imaging modalities.

Results

The interobserver reproducibility for the AO classification was 0.28 for X-rays, 0.33 for CT scan and 0.28 for 3DR. For the EVJE classification, these coefficients were 0.50 for X-rays, 0.35 for CT scan and 0.47 for 3DR. The agreement rate between the two imaging modalities was between 0.38 and 0.58 for X-rays/CT scan and between 0.79 and 0.86 for CT scan/3DR.

Discussion

The primary objective of this study was not achieved. CT imaging does not improve the interobserver reproducibility of various classification systems for trochanteric fractures. However, by providing images as slices, the complex nature of fractures in this area was revealed. The challenges related to classifying various fractures are not exclusively related to a “readability” problem, but also an understanding and analysis problem.

Level of evidence

Prospective diagnostic study, level III.

El texto completo de este artículo está disponible en PDF.

Keywords : Trochanteric fractures, CT scan, 3D reconstruction


Esquema


© 2012  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 1

P. 46-51 - février 2013 Regresar al número
Artículo precedente Artículo precedente
  • The prevalence of acetabular anomalies associated with pistol-grip-deformity in osteoarthritic hips
  • I. Ipach, F. Mittag, C. Walter, R. Syha, P. Wolf, T. Kluba
| Artículo siguiente Artículo siguiente
  • Trabecular microarchitecture in established osteoporosis: Relationship between vertebrae, distal radius and calcaneus by X-ray imaging texture analysis
  • F. Mallard, B. Bouvard, P. Mercier, P. Bizot, P. Cronier, D. Chappard

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.