Suscribirse

Ocular Biometric Parameters Associated With Intraocular Pressure Reduction After Cataract Surgery in Normal Eyes - 20/06/13

Doi : 10.1016/j.ajo.2013.02.003 
Hyun Seung Yang a, Junsung Lee b, Sangkyung Choi b, ⁎
a Department of Ophthalmology, Asan Medical Center, Seoul, South Korea 
b Department of Ophthalmology, Veterans Health Service Medical Center, Seoul, South Korea 

∗Inquiries to Sangkyung Choi, Department of Ophthalmology, Veterans Health Service Medical Center, Doonchon2-Dong, Gangdong-gu, Seoul 134-791, South Korea

Abstract

Purpose

To evaluate the ocular biometric parameters associated with intraocular pressure (IOP) reduction after phacoemulsification.

Design

Prospective, observational case series.

Methods

The study included 999 patients who had undergone uncomplicated phacoemulsification. IOP and ocular biometric parameters were checked preoperatively and 3 months postoperatively using anterior segment optical coherence tomography, optical biometry, and ultrasonic biomicroscopy. The relationship between IOP change and the parameters, including preoperative IOP, anterior chamber depth, axial length, angle opening distance at 500 μm, anterior chamber area, corneal thickness, lens thickness, and iris thickness at 750 μm, was evaluated.

Results

The mean patient age was 67.1 ± 4.3 years. The average change in IOP was −1.6 mm Hg (−11.8%). In univariate analysis, axial length, corneal thickness, and iris thickness were not significantly associated with IOP reduction. However, preoperative IOP, anterior chamber depth, angle opening distance, anterior chamber area, and lens thickness were significantly associated with IOP change (P < .05). Furthermore, changes in anterior chamber depth (standardized coefficient beta [B] = −0.082), angle opening distance (B = −0.095), and anterior chamber area (B = −0.380) were more strongly correlated with IOP change than were preoperative factors (B = −0.078, B = −0.071, and B = −0.067, respectively). In multivariate analysis, preoperative IOP, lens thickness, angle opening distance change, and anterior chamber area change were significantly associated with IOP change (P < .005).

Conclusion

In addition to preoperative IOP and lens thickness, parameters such as changes in anterior chamber area and angle opening distance were significantly associated positively with reduced IOP after phacoemulsification.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2013  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 156 - N° 1

P. 89 - juillet 2013 Regresar al número
Artículo precedente Artículo precedente
  • Cataract Extraction Outcomes and the Prevalence of Zonular Insufficiency in Retinitis Pigmentosa
  • Mark Samuel Dikopf, Clement Chikai Chow, William Francis Mieler, Elmer Yuchen Tu
| Artículo siguiente Artículo siguiente
  • Comparisons of Outcomes With Different Intervals Between Adjunctive Ranibizumab and Photodynamic Therapy for Polypoidal Choroidal Vasculopathy
  • Taku Sato, Shoji Kishi, Hidetaka Matsumoto, Ryo Mukai

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.