Suscribirse

Relation between lower extremity alignment and proximal femur anatomy. Parameters during total hip arthroplasty - 25/06/13

Doi : 10.1016/j.otsr.2013.02.006 
M. Ollivier, S. Parratte , L. Lecoz, X. Flecher, J.-N. Argenson
 Motion research and musculo-skeletal institute, Southern Teaching Hospital Center, Sainte-Marguerite Hospital, 270, boulevard Sainte-Marguerite, 13009 Marseille, France 

Corresponding author. Tel.: +33 491 745 011; fax: +33 491 745 625.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Tuesday 25 June 2013
This article has been published in an issue click here to access

Summary

Background

Lower extremity alignment correlates with native femoral offset. Eventual impact of the change in femoral offset induced by total hip arthroplasty (THA) on lower extremity alignment has not been documented.

Hypothesis

THA significantly changes lower extremity alignment, and the change correlates with the change in femoral offset.

Materials and methods

We conducted a prospective study of 200 patients with primary hip osteoarthritis or avascular femoral head necrosis who underwent cementless THA. Pre-operative computed-tomography templating was performed and the femoral component was then custom-manufactured to replicate the native femoral anatomy. Mean age was 58 years (range, 28–83 years). Before and at least two years after THA, two observers who were not involved in the surgical procedures used standing antero-posterior long-leg radiographs to determine the mechanical axis of the lower-limb (hip-knee-ankle [HKA] angle), femoral offset, neck-shaft angle (NSA), and lower-limb length discrepancy (LLLD).

Results

Mean values pre-operatively and at last follow-up were as follows: HKA angle, 179.2°±3.9° (range, 170.5° to 190.5°) and 177.7°±3.5°(range, 173° to 187°); LLLD, −0.7mm (range, –30mm to+25mm) and+5.1mm (range, –7mm to+21mm); NSA, 134°±7.5° (range, 100° to 124°) and 135°±4.2° (range, 124° to 146°); and femoral offset, 42±7.8mm (range, 24mm to 68mm) and 49±7.5mm (range, 33mm to 70mm). Although THA significantly altered lower-limb alignment, univariate and multivariate analyses showed no significant association between the change in HKA angle and the change in femoral offset.

Discussion

Lower-limb alignment was significantly affected by THA, although the HKA angle changes were small. The small impact of THA on HKA angle values may be ascribable to efforts aimed at replicating the native femoral offset during arthroplasty, as well as to the limited sample size and to potential measurement errors related to the small size of the changes. Our results suggest that, provided careful attention is directed to replicating the native femoral offset, THA in patients with limited pre-operative anatomical abnormalities may have no major impact on the biomechanical parameters of the ipsilateral knee.

Level of evidence

Level III, prospective diagnostic study.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasty, Femoral offset, Lower extremit alignment, Adult, Biomechanics


Esquema


© 2013  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.