Summary

Background

Distal femur torsion (DFT) is a crucial parameter in knee replacement surgery. The reference standard for measuring DFT is posterior condylar angle (PCA) measurement using computed tomography (CT). The objective of this study was to assess the feasibility and reliability of a radiographic PCA measurement method.

Materials and methods

We studied 125 osteoarthritic knees in 79 patients (42 women and 37 men) with a mean age of 71.6±8.8years (range 47 to 86 years); 32 knees were aligned, 85 in varus, and eight in valgus. DFT was measured on an antero-posterior (AP) radiograph of the knee in 90° of flexion (known as the seated AP view). The PCA was defined as the angle subtended by the tangent to the posterior condyles and the transepicondylar axis (anatomic PCA [aPCA]) or the line connecting the lateral epicondyle to the medial sulcus (surgical PCA [sPCA]). The PCA was conventionally recorded as positive in the event of external torsion and negative in the event of internal torsion. PCA measurements were performed three times by each of five observers to allow assessments of inter-observer and test-retest reliabilities.

Results

aPCA was consistently negative (mean, −6.1±1.6°) (range, 0 to −10°); inter-observer and test-retest reliability were satisfactory (0.54<rw0.80). sPCA was positive in 41 knees and negative in 84 knees) (mean, −0.3±1.4°) (range, −5° to +2°); inter-observer and test-retest reliabilities were poor (0.28<r<0.69). A weak but significant correlation was found between aPCA and coronal alignment, with a trend towards greater internal torsion in the group of valgus knees.

Conclusion

Radiographic measurement of DFT is simple and non-invasive. Measurement reproducibility was satisfactory for aPCA but not for sPCA. aPCA showed marked inter-individual variability and tended to increase when the knee was in valgus. Mean aPCA values were comparable to those reported using CT. In contrast to CT, radiographic DFT measurement can easily be incorporated into the pre- and postoperative work-ups for knee replacement surgery, provided the patient can achieve 90° of knee flexion.

Level of evidence

Level IV, prospective cohort study.

El texto completo de este artículo está disponible en PDF.

Keywords : Total knee arthroplasty, Distal femoral torsion, Transepicondylar axis, Posterior condylar angle, Conventional radiography, Seated radiography


Esquema


© 2013  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.