Suscribirse

Distal radius fracture metaphyseal comminution: A new radiographic parameter for quantifying, the metaphyseal collapse ratio (MCR) - 12/09/13

Doi : 10.1016/j.otsr.2013.05.002 
S.H. Rhee , J. Kim
 Department of Orthopedic Surgery, Seoul National University Boramae Medical Center, Seoul, South Korea 

Corresponding author. Department of Orthopedic Surgery, Seoul National University Boramae Medical Center, 39, Boramae-gil, Dongjak-gu, Seoul 156-707, South Korea. Tel.: +82 2 870 2317; fax: +82 2 831 2826.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Thursday 12 September 2013
This article has been published in an issue click here to access

Summary

Introduction

Metaphyseal comminution is widely considered as a key radiographic parameter that predicts fracture instability for distal radius fractures. However, no quantitative parameter is available to measure this degree of comminution. To quantify metaphyseal comminution objectively, the authors devised and validated the metaphyseal collapse ratio, a new radiographic index.

Materials and methods

Seventy-four cases of distal radius fracture in the elderly were included in this analysis. After closed reduction, a strictly lateral plain radiograph was obtained and digitally adjusted. The metaphyseal collapse ratio (MCR) was calculated expressing the maximal radiolucent extent as a percentage of the intercortical distance. Furthermore, correlations between MCR and age, gender, DXA scores, and other radiographic parameters, namely, radial shortening, volar tilt, radial inclination, and the presence of an associated ulnar fracture were investigated.

Results

Mean metaphyseal collapse ratio in the cohort was calculated to be 51.7% by one observer and 53.7% by a second, showing good interobserver and mean intraobserver reliability (0.812, P<0.001 and 0.826, P<0.001, respectively). MCR was found to be significantly correlated with conventionally accepted radiographic parameters of fracture instability, that is, radial shortening (P<0.001), volar tilt (P<0.001), and radial inclination (P=0.002), but not with age, gender, DXA scores, and the presence of a combined ulnar fracture.

Conclusions

Metaphyseal collapse ratio, a novel radiographic parameter, was found to provide a reliable measure of metaphyseal comminution, and to be significantly correlated with other radiographic parameters that predict distal radius fracture instability.

Level of evidence

Level III, diagnostic.

El texto completo de este artículo está disponible en PDF.

Keywords : Distal radius fracture, Metaphyseal comminution, Radiographic parameter


Esquema


 This study received approval from the IRB.


© 2013  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.