Summary

Treating patients with severe neuromuscular scoliosis by long spinal fusion improves their quality of life and provides significant comfort for the patient and caregivers. But lumbosacral (L5-S1) fusion is challenging in these patients because of the significant deformities that result in poor bone anchoring quality and a risk of impingement between the skin and implants. In 1993, Jackson described a L5-S1 fusion technique using S1 pedicle screws and intrasacral rods (implanted under X-ray guidance) that are linked to the construct above with connectors. The goal of this study was to evaluate the clinical and radiological results and the postoperative complications of a simplified version of this technique, which does not require connectors or X-ray guidance.

Materials and methods

Thirty-three patients were evaluated with a minimum follow-up of 4years (average 82months). Frontal balance, sagittal balance, Cobb angle, sacral slope, lumbar lordosis and lateral pelvic tilt in the frontal plane were assessed on preoperative, postoperative and follow-up X-rays. Intraoperative and postoperative complications were recorded.

Results

Complete fusion was obtained in 32 patients. The average Cobb angle was 62° initially and was reduced to 20° after surgery and 24° at the final follow-up. The average lateral pelvic tilt was 10.3° (0 to 26°) initially; it was surgically corrected to an average of 7.5° (0 to 24°); the average secondary loss of correction was 1.2° (0 to 9°). The sacral slope was corrected to an average of 11.2°; an average of 0.2° had been lost at the last follow-up (0 to 18°). Although the average for lumbar lordosis was unchanged, the standard deviation went from 29° to 16° after the corrective surgery and 17° at the last follow-up, with large cluster of measurements around the average value of 40°. The deformity correction was comparable to the results with other techniques (Galveston, sacroiliac screws); the complication rate was similar but the non-union rate was lower. This simplified Jackson technique appears to be an effective, simple method for L5-S1 fusion to correct neuromuscular scoliosis as it provides stable results over time.

Level of evidence

Level IV, retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Iliosacral fixation, Lateral pelvic tilt, Neuromuscular scoliosis, Jackson technique


Esquema


© 2013  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 7

P. 845-851 - novembre 2013 Regresar al número
Artículo precedente Artículo precedente
  • Bone defect reconstruction in children using the induced membrane technique: A series of 14 cases
  • R. Gouron, F. Deroussen, M.-C. Plancq, L.-M. Collet
| Artículo siguiente Artículo siguiente
  • Endoscopic repair of partial-thickness undersurface tears of the gluteus medius tendon
  • M. Thaunat, R. Chatellard, E. Noël, B. Sonnery-Cottet, L. Nové-Josserand

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.