Contribution of patient-specific cutting guides to lower limb alignment for total knee arthroplasty - 03/04/14

Doi : 10.1016/j.otsr.2014.03.006 
H. Moubarak, J. Brilhault
 Orthopaedics and Trauma Surgery Department I, Hôpital Trousseau, CHRU Tours, 37044 Tours cedex 1, France 

Corresponding author. Orthopaedic Surgery Department I, CHRU de Tours, 37044 Tours cedex 9, France. Tel.: +33 2 34 38 94 64; fax: +33 2 47 47 83 85.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Thursday 03 April 2014
This article has been published in an issue click here to access

Abstract

Patient-specific cutting guides (PSCG) are an extension of preoperative planning for total knee arthroplasty (TKA). We wanted to evaluate their contribution to postoperative lower limb alignment. This study involved primary TKA cases being performed with PSCG between 10/05/2010 and 05/03/2013 and then followed prospectively. The analysis involved the PSCG usage and postoperative measurement of the patient's HKA, medial distal femoral joint angle (MDFA) and medial proximal tibia joint angle (MPTA). Of the 104 eligible cases, 68 were included; 11 of these cases were not performed completely with the PSCG as initially planned. Thus we compared these 11 cases with the 57 where PSCG were used. The preoperative HKA in the included cases was 175.8°±7.8; the postoperative angles on average were 179.2°±2.9 for the HKA, 89.9°±1.6 for the MDFA and 89.0°±2.3 for the MPTA. The average postoperative deviation from the target values was 2.22°±2.14 for the HKA angle, 1.07°±1.15 for the MDFA and 1.66°±1.90 for the MPTA. There were no significant differences between the two groups in any of the measurements. The lower limb alignment goal was achieved in 50 cases (73%), with 41 of these achieved with PSCG (82%). Of the 18 cases where the target was not achieved, PSCG were used 16 times (88%). In this study cohort, lower limb alignment was not significantly closer to an HKA of 180° or achieved more often with the use of PSCG versus standard instrumentation. Since the results of the two groups can be superimposed, we found no evidence that use of PSCG improves postoperative lower limb alignment.

Level of evidence

IV.

Study type

Cohort.

El texto completo de este artículo está disponible en PDF.

Keywords : Total knee arthroplasty, Patient-specific instrumentation, Accuracy


Esquema


© 2014  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.