Suscribirse

Usefulness and reliability of two- and three-dimensional computed tomography in patients older than 65 years with distal humerus fractures - 05/04/14

Doi : 10.1016/j.otsr.2014.01.003 
A. Jacquot a, N. Poussange b, J.-L. Charrissoux c, P. Clavert d, L. Obert e, L. Pidhorz f, F. Sirveaux a, P. Mansat f, g, T. Fabre b,
a Service d’orthopédie-traumatologie, centre chirurgical E.-Galle, 49, rue Hermite, 54000 Nancy, France 
b Service d’orthopédie-traumatologie, place Amélie-Raba-Leon, 33076 Bordeaux cedex, France 
c Département d’orthopédie-traumatologie, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges cedex, France 
d Centre de chirurgie orthopédique et de la main, 10, avenue Achille-Baumann, 67400 IllkirchGraffenstaden, France 
e Chirurgie orthopédique, traumatologique et plastique, centre hospitalier de Besançon, 2, boulevard Fleming, 25030 Besançon, France 
f Service de traumatologie, chirurgie orthopédique, centre hospitalier, 194, avenue Rubillard, 72037 Le Mans, France 
g Institut de l’appareil locomoteur, CHU de Toulouse, place du Dr-Baylac, 31059 Toulouse, France 

Corresponding author. Service d’orthopédie-traumatologie, place Amélie-Raba-Leon, 33076 Bordeaux cedex, France Tel.: +33 5 56 79 55 44.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Saturday 05 April 2014
This article has been published in an issue click here to access

Abstract

Background

Distal humerus fractures are difficult to characterise and to classify according to the AO system. In this multicentre study, our objectives were to assess the usefulness of computed tomography (CT) and to measure intra-observer and inter-observer reliability according to observer experience.

Materials and methods

An online survey of professional practice was performed using a questionnaire based on a clinical case. Participants were asked to determine the AO classification using radiographs then to reappraise their answers after the addition of CT images. For the reliability study, 16 observers in five centres evaluated radiographs and CT scans of 26 distal humerus fractures. They used the radiographs to determine the AO classification and assess the main fracture characteristics then reappraised their findings after adding the CT images. The radiographs and 2D CT images were read twice at an interval of 2 weeks, and during the second reading, 3D CT images were available also. At least 1 month later, the same observers performed similar readings 2 weeks apart (radiographs and 2D CT images at the first reading and addition of 3D CT images at the second reading).

Results

Correct fracture classification was achieved in 95% of cases with the CT images compared to only 73% with the radiographs. CT led to diagnostic and therapeutic changes in 90% and 25% of cases, respectively. Inter-observer reliability was poor for both AO classification and fracture characteristics, not only with the radiographs and 2D CT images, but also with the added 3D CT images. In contrast, intra-observer reliability improved after the addition of 3D CT images. Assessment accuracy was influenced by image quality and geographic origin of the observer but not by observer experience.

Conclusion

CT improves diagnostic accuracy and, in some cases, changes the surgical strategy. In our study of a large number of observers, CT did not improve inter-observer agreement about the study variables. Intra-observer agreement was improved by 3D CT but not by 2D CT. Accuracy was not influenced by years of observer experience but was dependent on image quality, proficiency with computer-based tools and, above all, image observation and interpretation.

Level of evidence

Level III.

El texto completo de este artículo está disponible en PDF.

Keywords : Distal humeral fracture, Computed tomography, Inter-observer reliability


Esquema


© 2014  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.