Suscribirse

Does Biolox® Delta ceramic reduce the rate of component fractures in total hip replacement? - 12/08/14

Doi : 10.1016/j.otsr.2014.05.010 
P. Massin a, , R. Lopes b, B. Masson c, D. Mainard d
the

French Hip & Knee Society (SFHG)e

a EA REMES, université Paris-Diderot, Sorbonne-Paris-Cité, hôpital Bichat, 46, rue Henri-Huchard, 75010 Paris, France 
b Hôtel-Dieu, université de Nantes, 1, place Alexis-Ricordeau, 44093 Nantes cedex 1, France 
c 18, rue des Potiers, 31320 Vieille-Toulouse, France 
d Université de Lorraine, hôpital Central, 29, avenue de Lattre-de-Tassigny, 54035 Nancy, France 
e 56, rue Boissonade, 75014 Paris, France 

Corresponding author. Tel.: +33 1 40 25 75 03; fax: +33 1 40 25 71 84.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Tuesday 12 August 2014
This article has been published in an issue click here to access

Abstract

Biolox® Delta ceramic has been optimized with nano-sized, yttria-stabilized tetragonal zirconium and strontium oxide to help limit cracking propagation. Although its mechanical properties are better than those of earlier generation ceramics, existing data on this material are limited, thus the goals of this study were to determine: 1) the remaining rate of implant fracture; 2) the ideal combination of head diameter and component position. Hypothesis. We hypothesized that the use of the ceramic composite Biolox® Delta had reduced the risk of implant fracture. Materials and methods. The bibliographic search (in Pubmed database with the key words «ceramic fracture» and «total hip prosthesis ») identified 46 articles on fractures in third or fourth generation ceramic components, including 5 involving Biolox® Delta. Manufacturer's data and ANSM (Agence nationale de sécurité du médicament et des produits de santé) (National Agency for Safety of Drugs and Medical Products) reports were compared with the few clinical cases published in the literature. Results. According to the manufacturer (CeramTec GmbH, Plochingen, Germany), the use of Biolox® Delta ceramic has reduced the rate of femoral head fractures to 0.003% compared to 0.021% with alumina ceramic. The fracture rate of liners has remained stable, at approximately 0.03%. The number of ANSM reports confirmed these tendencies. The rate of head component fractures decreases as the head diameter increases. The quality of impaction on the morse taper (cleanliness of the taper, insertion along the axis) plays an important role. Although it is generally only available for cup sizes above 50mm, a 36-mm head diameter seems to be optimal because it prevents impingement between the cup rim and the neck of the stem, without increasing micro-separation with larger diameters. Conclusion. Although Biolox® Delta ceramic is more resistant to fractures than alumina ceramic, it can be fractured under suboptimal implantation conditions including edge loading. Its use requires the same precautions as other hard-on-hard bearings and requires special attention to cup position, insertion on or in morse tapers and adjustment of leg length.

Level of evidence

V expert's opinion.

El texto completo de este artículo está disponible en PDF.

Keywords : Biolox® Delta ceramic, Total hip arthroplasty, Ceramic fracture, Edge loading


Esquema


© 2014  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.