Quality check of cardiac MRI exams for Fallot patients: Interest of a simple formula to detect invalid exams - 24/08/14

Doi : 10.1016/j.acvd.2014.07.019 
K. Kecir 1, M. Beaumont 2, B. Chen 3, P.Y. Marie 4, J. Felblinger 5, L. Bonnemains 6, 7, 8,
1 Pédiatrie, CHU de Nancy, Nancy, France 
2 CIC-IT, CHU de Nancy, Nancy, France 
3 IADI, Nancy-Université, Nancy, France 
4 Département Imagerie, CHU de Nancy, Nancy, France 
5 INSERM U947, Nancy-Université, Nancy, France 
6 Cardiologie Infantile, CHU de Nancy, Nancy, France 
7 Cardiologie Infantile, CHU de Strasbourg, Strasbourg, France 
8 IADI, Université de Lorraine, Nancy, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Resumen

Purpose

Cardiac MRI (CMR) is the key exam for Fallot patients but remains tricky. The CMR report should at least mention left and right ventricle end-diastole volumes (Vl and Vr), ejection fraction (EFl and EFr) and pulmonary regurgitation (PR). Obviously, these variables are linked together by basic physiology rules and indeed Vl×EFl=Vr×EFr×(1-PR). We investigated the interest of using such formula as quality check during Fallot CMR exams in our center.

Methods

98 consecutive CMR examinations for Fallot (or Fallot-like) cardiopathy between 2010 and 2014 were retrospectively included. The exams failing to pass the formula (with a 10% tolerance) constituted the Invalid-group and a control group of the same size was also constituted. CMR of both groups were randomly submitted to a blinded senior observer. The inter-observer limits of agreements were compared for the different variables within both groups.

Results

(Fig. 1) 12 CMR (12%) failed to pass the validation formula. From the 24 reanalyzed CMR, only 4 failed to pass the formula (all from the Invalid-group). Two had persistent defect (VSD or ASD) which were not mentioned to the radiologist and not detected during the CMR. Two had significant artefacts in the aorta or pulmonary trunk due to sterna wires. The inter-observer disagreements for the 8 other CMR of the Invalid-group concerned the Right ventricle end-diastole volume (P<0.05).

Conclusion

The use of a simple formula as quality check of CMR examinations for Fallot patients was useful to detect a total of 12% of CMR with issues. 8% of the CMR corresponded to uncertain right ventricle contours, 2% to persistent septal defects that should have been noticed during the examination and 2% to unreliable aortic or pulmonary flow due to artifacts. The formula could have permitted either to detect the anomalies or at least to conclude that the quality of the exams was impaired.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2014  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 107 - N° 8-9

P. 492 - août 2014 Regresar al número
Artículo precedente Artículo precedente
  • Knowledge-based 3D reconstruction compared to MRI for evaluation of right ventricular volumes and function in congenital heart diseases affecting the right ventricle
  • O. Guillard, D. Khraiche, M. Ladouceur, L. Iserin, F. Raimondi, D. Bonnet
| Artículo siguiente Artículo siguiente
  • Feasibility and accuracy of left ventricular volumes and ejection fraction measured by different echocardiographic methods in congenital heart diseases involving the right ventricle
  • M. Meot, D. Khraiche, M. Ladouceur, F. Raimondi, O. Guillard, D. Bonnet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.