Abstract

Background

Although cross-linked polyethylene is resistant to wear in comparison to conventional polyethylene, it remains unknown whether it can decrease the wear-related revision rate of total hip arthroplasty.

Objectives

To determine whether cross-linked polyethylene decreases the wear-related revision rate of total hip arthroplasty compared with conventional polyethylene.

Data sources

Electronic databases, including PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials, were queried from inception to July 6, 2013.

Study selection

Randomized controlled trials (RCTs) comparing cross-linked polyethylene with conventional polyethylene were included. In addition, the standard 28-mm femoral head was used, and follow-up was performed for a minimum of 5 years. The primary outcome assessed was wear-related revision. The secondary outcome measures evaluated were the incidence of osteolysis, the linear wear rate, and the linear head penetration.

Data synthesis

The Cochrane Collaboration's tool for assessing the risk of bias was used for quality assessment. Data from eligible studies were pooled using a random effects model.

Results

Eight studies involving 735 patients were included in this study. Meta-analysis showed there was no significant difference between cross-linked and conventional polyethylene group in terms of osteolysis or wear-related revision. The pooled mean differences were significantly less for the linear wear rate and linear head penetration for cross-linked polyethylene than for conventional polyethylene.

Limitations

The studies differed with respect to the cross-linked liner brands, manufacturing processes, and radiological evaluation methods. Moreover, the follow-up periods of the RCTs were not long enough.

Conclusions

The current limited evidence suggests that cross-linked polyethylene significantly reduced the radiological wear compared with conventional polyethylene at midterm follow-up periods. However, there is no evidence that cross-linked polyethylene had an advantage over conventional polyethylene in terms of reducing osteolysis or wear-related revision. Nevertheless, future long-term RCTs on this topic are needed.

Key findings

Cross-linked polyethylene significantly reduced radiological wear but not osteolysis or wear-related revision in comparison to conventional polyethylene at midterm follow-up periods.

Level of evidence

Level I, systematic review of level I studies.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasty, Polyethylene, Cross-linked, Meta-analysis


Esquema


© 2014  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.