Abstract

Background

The many radiographic views suggested for evaluating anterior femoroacetabular impingement (FAI), due to a cam effect, are not specific for this condition and have not been proven of diagnostic value in studies, including control groups. Using a new and specific radiographic view, we evaluated the reproducibility of the main radiographic criteria for FAI, determined normal values for these criteria in a control group, and established diagnostic threshold values.

Hypothesis

This specific view offers good reproducibility and effectively detects abnormal values of criteria for FAI.

Materials and methods

Inter-observer and intra-observer reproducibility of specific radiographic criteria (αangle and modified head-neck offset [HNO]) were computed from preoperative and postoperative radiographs of 96 hips (75 patients, 61 males and 14 females) using the specific 45°-45°-30° frog-leg view (F45 view). Values in the group with FAI were compared to those in a control group of asymptomatic volunteers (100 hips, 27 males and 23 females).

Results

Inter-observer and intra-observer reproducibility was very good, with intra-class correlation coefficients of 0.955and 0.987, respectively, for the α angle and of 0.895 and 0.984, respectively, for the HNO. Mean values of both parameters differed significantly between the FAI and control groups: 73.9° (53° to 96°) vs. 49.3° (35° to 69°) for the αangle, respectively; and 2.5mm (–4.6 to 9.4) vs. 7.6mm (1.7 to 11.8) for HNO, respectively. The normal values defined as the boundary of the 95% reference interval in the control group were<60.2° for the α angle, and>4.6mm for the HNO.

Discussion

The45°-45°-30° frog-leg view is useful for diagnosing FAI due to a cam effect. This view is easy to perform, and the thresholds determined in our study assist in its interpretation: α angle values>58° in females and>63° in males indicate cam-type femoral geometry. In both genders, HNO values<5mm support a diagnosis of anterior FAI.

Level of evidence

Level III, case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Femoroacetabular impingement, Cam effect, Alpha angle, Head-neck offset, Frog-leg view


Esquema


 This work was awarded the first Advanced Orthopaedic Surgery Degree (Diplôme d’Études Spécialisées Complémentaires en Chirurgie Orthopédique) prize from the Academy for Orthopaedics and Traumatology (AOT) at the 86th French SoFCOT meeting.


© 2014  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 100 - N° 8

P. 843-848 - décembre 2014 Regresar al número
Artículo precedente Artículo precedente
  • Contents
| Artículo siguiente Artículo siguiente
  • Clinical and MRI results in 67 patients operated for gluteus medius and minimus tendon tears with a median follow-up of 4.6 years
  • K.G. Makridis, M. Lequesne, H. Bard, P. Djian

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.