Suscribirse

Reproducibility of condylar twist angle measurement using computed tomography and axial radiography of the distal femur - 06/12/14

Doi : 10.1016/j.otsr.2014.07.025 
H. Kobayashi a, , b , M. Aratake a, Y. Akamatsu b, N. Mitsugi a, N. Taki a, T. Saito b
a Department of Orthopedic Surgery, Yokohama City University Medical Center, 4–57, Urafune-cho, Minami, Yokohama, Kanagawa 232-0024, Japan 
b Department of Orthopedic Surgery, Yokohama City University Graduate School of Medicine, 3–9, Fukuura, Yokohama, Kanagawa 236-0004, Japan 

Corresponding author at: Department of Orthopedic Surgery, Yokohama City University Medical Center, 4–57, Urafune-cho, Minami, Yokohama, Kanagawa 232-0024, Japan. Tel.: +81457872655.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

It is essential to understand rotational alignment of the distal femur when performing total knee arthroplasty (TKA). Several rotational landmarks including condylar twist angle (CTA) are used for preoperative planning and during TKA. Axial radiography of the distal femur is used for measuring the CTA, and assessing rotational alignment in TKA. The aim of this study was to investigate the reliability and the reproducibility of the CTA using two different methods and evaluate if CTA differed between varus and valgus knees and between normal and osteoarthritic knees.

Materials and methods

CTA were obtained from 144 knees (77 patients) having total knee or hip arthroplasty using computed tomography (CT) and axial radiography. Subjects were divided into five groups based on femorotibial angle (FTA) and into four groups based on the severity of knee osteoarthritis. The intra-observer and inter-observer reliabilities of these methods and inter-method differences were evaluated.

Results

The mean CTA was 7.02° with axial radiography, and 6.87° with CT images. There were no significant differences among the five FTA groups and among the four osteoarthritis groups. In total, intra-/inter-observer, and inter-method intraclass correlation coefficients were substantial or almost perfect in the scoring system of Landis et al. However, discrepancies ≥2° between the two methods were observed in more than 20% of knees.

Conclusion

The CTA should be reassessed by more than two observers or two methods for precise preoperative TKA planning in cases where it is difficult to identify the bony landmarks for CTA measurements.

Level of evidence

Level III.

El texto completo de este artículo está disponible en PDF.

Keywords : Condylar twist angle, Posterior condylar angle, Computed tomography, Axial radiograph, Rotational alignment, Total knee arthroplasty (TKA)


Esquema


© 2014  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 100 - N° 8

P. 885-890 - décembre 2014 Regresar al número
Artículo precedente Artículo precedente
  • Current state of anterior cruciate ligament registers
  • P. Boyer, B. Villain, A. Pelissier, P. Loriaut, B. Dalaudière, P. Massin, P. Ravaud
| Artículo siguiente Artículo siguiente
  • Vascular injuries during closing-wedge high tibial osteotomy: A cadaveric angiographic study
  • A. Darnis, V. Villa, C. Debette, S. Lustig, E. Servien, P. Neyret

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.