Suscribirse

Can reverse shoulder arthroplasty in post-traumatic revision surgery restore the ability to perform activities of daily living? - 01/04/15

Doi : 10.1016/j.otsr.2014.12.007 
M.W. Maier a, , F. Zeifang a , M. Caspers a , T. Dreher a , M.C. Klotz a , O. Rettig a , S.I. Wolf a , P. Kasten b
a Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany 
b Orthopedic Surgery Center (OCC) Tübingen, University Department of Orthopedic Surgery, Hoppe-Seyler-Strasse, 3, 72076 Tübingen, Germany 

Corresponding author. Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstraβe, 200a, 69118 Heidelberg, Germany. Tel.: +49 6221 56 25000; fax: +49 6221 6347.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Failed shoulder arthroplasty and failed internal fixation in fractures of the proximal humerus can benefit from implantation of a reverse total shoulder arthroplasty (RSA). While there is some evidence that RSA can improve function regarding range of motion (ROM), pain, satisfaction, and strength, there is sparse data how this translates into activities of daily living (ADLs). A marker-based 3D video motion analysis system has recently been designed that can measure changes of ROM in dynamic movements in every plane. The hypothesis was that a gain of maximum ROM also translates into the ability to perform ADLs and into a significant increase of ROM in ADLs.

Materials and methods

Six consecutive patients (5 women, 1 man; 2× failed arthroplasty, 4× failed open reduction and internal fixation) who received RSA were examined the day before and 1 year after shoulder replacement. A 3D motion analysis system using a novel upper extremity model measured active maximum values and ROM in four ADLs.

Results

Comparing the pre- to the 1-year postoperative status, RSA resulted in a significant increase in mean maximum values for active flexion (humerus to thorax) of 37° (S.D. ±23°), from 50 to 87° [P=0.005], and for active abduction averaging of 17° (S.D. ±13°), from 52 to 69° [P=0.027]. The extension decreased significantly by about 8° (S.D. ±16°), from a mean of 39 to 31° [P=0.009]. For active adduction and internal and external rotation, there were trends for improvements, but no significant changes. Only three additional tasks of the ADL (out of 13/24 preoperatively) could be performed after revision surgery. Comparing the preoperative to the postoperative ROM in the ADLs in flexion/extension, ROM improved significantly in one (“tying an apron”) of four ADLs. There were no significant changes in the abduction/adduction and internal/external rotation in any ADLs.

Conclusion

RSA in revision cases significantly improved maximum active flexion and abduction, but decreased extension in this series. However, the patients were only able to use this greater ROM to their benefit in one of four ADLs.

El texto completo de este artículo está disponible en PDF.

Keywords : Reverse shoulder arthroplasty, Revision, Outcome, Failed arthroplasty, Failed osteosynthesis, Marker-based system, Upper extremity, Biomechanical model, Functional testing, Activity of daily living


Esquema


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 2

P. 191-196 - avril 2015 Regresar al número
Artículo precedente Artículo precedente
  • Evaluation of a new baseplate in reverse total shoulder arthroplasty – comparison of biomechanical testing of stability with roentgenological follow up criteria
  • U. Irlenbusch, G. Kohut
| Artículo siguiente Artículo siguiente
  • Intrinsic and extrinsic risk factors for nonunion after nonoperative treatment of midshaft clavicle fractures
  • W. Liu, J. Xiao, F. Ji, Y. Xie, Y. Hao

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.