Biomechanical study of dynamic changes in L4–L5 foramen surface area in flexion and extension after implantation of four interspinous process devices - 01/04/15

Doi : 10.1016/j.otsr.2014.11.016 
C. Hirsch a, , C. Breque b, S. Ragot c, H. Pascal-Mousselard a, J.-P. Richer d, M. Scepi d, F. Khiami a
a Department of Orthopaedic Surgery, hôpital de la Pitié-Salpêtrière, AP–HP, UPMC University, 75013 Paris, France 
b Laboratoire d’anatomie, Université de Poitiers, 15 rue de l’Hôtel Dieu, TSA 71117, 86073 Poitiers Cedex 9, France 
c Clinical Investigation Centre, Poitiers University, Poitiers, France 
d Anatomy Department, Poitiers University, Poitiers, France 

Corresponding author. Service de chirurgie orthopédique et traumatologique, hôpital de la Pitié-Salpêtrière, AP–HP, UPMC University, 47-83, boulevard de l’Hôpital, 75013 Paris, France. Tel.: +33 6 18 47 39 59.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Lumbar spinal stenosis is a major public health issue. Interspinous devices implanted using minimally invasive techniques may constitute an alternative to the reference standard of bony decompression with or without intervertebral fusion. However, their indications remain unclear, due to a paucity of clinical and biomechanical data. Our objective was to evaluate the effects of four interspinous process devices implanted at L4–L5 on the intervertebral foramen surface areas at the treated and adjacent levels, in flexion and in extension.

Materials and method

Six fresh frozen human cadaver lumbar spines (L2–sacrum) were tested on a dedicated spinal loading frame, in flexion and extension, from 0 to 10 N·m, after preparation and marking of the L3–L4, L4–L5, and L5–S1 foramina. Stereoscopic 3D images were acquired at baseline then after implantation at L4–L5 of each of the four devices (Inspace®, Synthes; X-Stop®, Medtronic; Wallis®, Zimmer; and Diam®, Medtronic). The surface areas of the three foramina of interest were computed.

Results

All four devices significantly opened the L4–L5 foramen in extension. The effects in flexion separated the devices into two categories. With the two devices characterized by fixation in the spinous processes (Wallis® and Diam®), the L4–L5 foramen opened only in extension; whereas with the other two devices (X-Stop® and Inspace®), the L4–L5 foramen opened not only in extension, but also in flexion and in the neutral position. None of the devices implanted at L4–L5 modified the size of the L3–L4 foramen. X-Stop® and Diam® closed the L5–S1 foramen in extension, whereas the other two devices had no effect at this level.

Conclusion

Our results demonstrate that interspinous process devices modify the surface area of the interspinous foramina in vitro. Clinical studies are needed to clarify patient selection criteria for interspinous process device implantation.

Level of evidence

Level IV. Investigating an orthopaedic device.

El texto completo de este artículo está disponible en PDF.

Keywords : Interspinous process device, Lumbar spinal stenosis, Biomechanics


Esquema


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 2

P. 215-219 - avril 2015 Regresar al número
Artículo precedente Artículo precedente
  • Clinically relevant heterotopic ossification after elbow fracture surgery: A risk factors study
  • C.C. Hong, N. Nashi, H.W. Hey, Y.H. Chee, D. Murphy
| Artículo siguiente Artículo siguiente
  • Relationship between autologous bone graft osteointegration and correction loss after antero-posterior spondylodesis of traumatic vertebral body fracture
  • D. Kubosch, L. Konstantinidis, P. Helwig, A. Hirschmüller, P.C. Strohm, N.P. Südkamp

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.