Suscribirse

Comparaison entre le coût d’une pose de cathéter veineux central d’insertion périphérique et d’une chambre implantable - 30/04/15

Doi : 10.1016/j.pharma.2014.08.001 
H. Viart a, , C. Combe a , T. Martinelli b, J. Thomas c, H. Hida a
a Service de pharmacie, centre hospitalier de Valence, 179, boulevard du Maréchal-Juin, 26953 Valence cedex, France 
b Service radiologie, centre hospitalier de Valence, 179, boulevard du Maréchal-Juin, 26953 Valence cedex, France 
c Direction de l’information médicale, centre hospitalier de Valence, 179, boulevard du Maréchal-Juin, 26953 Valence cedex, France 

Auteur correspondant.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 6
Iconografías 0
Vídeos 0
Otros 0

Résumé

Introduction

Le cathéter veineux central à insertion périphérique, souvent désigné par l’acronyme anglais « PICC Line » et les chambres implantables (PAC) sont deux types de cathéters centraux permettant l’administration de médicaments et les prélèvements sanguins. Ces deux accès étant très controversés (complications infectieuses et thrombotiques), il semble intéressant d’évaluer leur coût de pose et de les corréler aux ressources allouées par l’Assurance maladie.

Matériels et méthodes

L’évaluation prospective a porté sur l’observation de poses de PICC Lines et de PAC durant lesquelles ont été recueillis le matériel et les médicaments utilisés (coûts directs) ainsi que le temps d’utilisation de la salle et le personnel intervenant (coûts indirects).

Résultats

Le coût global d’une pose de PICC Line est de 220,2 euros et celui d’une chambre implantable de 286,6 euros en radiologie interventionnelle et de 666,3 euros au bloc opératoire.

Discussion-conclusion

Seule une pose de Picc Line en soins externes peut être valorisée. Le montant du remboursement alloué par l’Assurance maladie est alors de 110,4 euros. L’établissement réalise donc des poses sans bénéfice. Cependant, l’utilisation des PICC Lines offre aux patients un accès rapide à une voie veineuse centrale et donc une prise en charge thérapeutique optimale, principale mission des établissements publics de santé. Quant au PAC, ils ne rapportent que si la pose est effectuée lors d’une hospitalisation en ambulatoire. Sa pose en radiologie semble plus rentable puisque les coûts indirects sont beaucoup plus modérés.

El texto completo de este artículo está disponible en PDF.

Summary

Introduction

Peripherally Inserted Central Catheter or PICC Line and implanted subcutaneous ports are two types of central catheters allowing drug administration and blood samplings. These two devices are very controversial (because of infectious and thrombotic complications), it seemed interesting to estimate their cost of implantation and to correlate them with the reimbursement by the Health Insurance.

Materials and methods

Direct (material and drugs) and indirect (use of the room and staff) costs were prospectively evaluated for PICC Lines and implanted subcutaneous ports.

Results

The global costs of the implantation of a PICC Line and of an implanted subcutaneous port in the interventional radiology room and in the operating room were respectively evaluated at 220.2 €, 286.6 € and 666.3 €.

Discussion-conclusion

Only a PICC Line in outpatients can be reimbursed by the health insurance; which amounts to 110.4 €. The establishment therefore loses money with every implantation. However, PICC Lines offer to the patients a fast access to a central venous way and thus an optimal therapeutic care, fulfilling one of the main missions of the public health institutions. Implanted subcutaneous ports are economically worth being implanted only in ambulatory inpatients. Its implantation in radiology seemed more profitable because the indirect costs were much more moderate.

El texto completo de este artículo está disponible en PDF.

Mots clés : Cathéter veineux central d’insertion périphérique, Chambre implantable, Coûts

Keywords : Peripherally inserted central catheter, Implanted subcutaneous ports, Costs


Esquema


© 2014  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 73 - N° 3

P. 239-244 - mai 2015 Regresar al número
Artículo precedente Artículo precedente
  • Recensement et analyse des preuves sur le rôle et sur les retombées de l’activité pharmaceutique : développement d’un outil sur Internet
  • A. Guérin, C. Tanguay, D. Lebel, J.-F. Bussières

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.