Abbonarsi

Total knee arthroplasty revision with trabecular tantalum cones: Preliminary retrospective study of 51 patients from two centres with a minimal 2-year follow-up - 09/05/16

Doi : 10.1016/j.otsr.2016.02.010 
D. Girerd a, S. Parratte a, , A. Lunebourg a, F. Boureau b, c, M. Ollivier a, G. Pasquier b, c, S. Putman b, c, H. Migaud b, c, J.N. Argenson a
a Université Aix-Marseille, Hôpital Sainte-Marguerite, Institut du Mouvement et de l’appareil Locomoteur, Service de chirurgie orthopédique et traumatologie, UMR CNRS 787/AMU, 270, boulevard Sainte-Marguerite, 13009 Marseille, France 
b Centre Hospitalier Régional Universitaire, Service de chirurgie orthopédique et traumatologie, avenue Oscar-Lambret, 59037 Lille cedex, France 
c Université de Lille, rue Paul-Duez, 59000 Lille, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Successful management of large bone defects is of crucial importance when performing revision total knee arthroplasty (TKA). Trabecular tantalum cones may improve prosthesis fixation via their potential for reconstructing a stable metaphyseal support. The objective of this study was to evaluate the clinical and radiological outcomes and the complications of tantalum cones in revision TKA.

Hypothesis

Trabecular tantalum cones provide stable and durable metaphyseal reconstruction when used during revision TKA.

Material and methods

Trabecular Metal™ cones (Zimmer, Warsaw, IN, USA) were used for 52 revision TKAs in 51 patients (mean age, 68±9 years) managed in two centres between 2008 and 2013. A rotating hinge prosthesis was chosen for 38 (73%) knees and a condylar constrained knee prosthesis for 14 (27%) knees, with 37 tibial and 34 femoral cones. The two most common reasons for revision surgery were aseptic loosening (n=22, 42%) and infection (n=19, 37%). The bone loss was severe in most cases. At each centre, after a mean follow-up of 34 months (range, 24–52 months), two independent observers assessed the Knee Society Score (KSS), range of motion, mechanical axis, and osteo-integration for each patient.

Results

Mean KSS increased from 46 preoperatively to 77 (P=0.001) at last follow-up and the mean KSS function from 39 to 57 (P=0.007). Mean range of motion improved from 93° (45°–120°) to 110° (65°–130°) (P=0.001). Mean postoperative mechanical axis was 180° (172°–190°). Radiographic evaluation showed evidence of osteo-integration for all cones. Four revisions were performed for recurrence of infection but none for mechanical failure.

Discussion

The findings of our study confirm the biomechanical and biological reliability of Trabecular Metal™ cones used to fill metaphyseal bone defects during revision TKA.

Level of evidence

IV, retrospective therapeutic study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Revision, Total knee arthroplasty, Knee, Trabecular metal cones, Tantalum, Bone defect


Mappa


© 2016  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 102 - N° 4

P. 429-433 - giugno 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Reproducibility of digital measurements of lower-limb deformity on plain radiographs and agreement with CT measurements
  • G. Sorin, G. Pasquier, E. Drumez, A. Arnould, H. Migaud, S. Putman
| Articolo seguente Articolo seguente
  • Joint awareness after total knee arthroplasty is affected by pain and quadriceps strength
  • Y. Hiyama, O. Wada, S. Nakakita, K. Mizuno

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.