Abbonarsi

Arthroscopic congruent-arc shoulder bone-block for severe glenoid bone defect: Preliminary report - 21/04/17

Doi : 10.1016/j.otsr.2016.11.023 
J. Kany a, , B. Codanda b, P. Croutzet a, R. Guinand a
a Clinique de l’Union, Shoulder, Boulevard de Ratalens, 31240 Saint-Jean, France 
b Sakra World Hospital, Bangalore, India 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Glenoid bone defect remains a surgical challenge in managing anterior shoulder instability. The technique first described by Latarjet has become the gold standard, but may fail to restore fully normal anatomy in case of severe “inverted-pear” glenoid bone defect. Likewise, the naturally “banana-shaped” coracoid process fails to match this flat shoulder. The congruent-arc modified Latarjet technique, which consists in pivoting the coracoid process through 90°, optimizes the contact surface, adapting to the glenoid curvature radius and increasing the articular surface of the graft.

Hypothesis

The present study hypothesis was that the congruent-arc bone-block technique could be performed entirely under arthroscopy. The main study objective was to assess the postoperative increase in glenoid surface area. The secondary objective was to assess whether the technique provided anatomic glenoid reconstruction.

Materials and methods

Five patients with inverted-pear glenoid were recruited in a preliminary prospective study. Immediate postoperative coracoid process length, width and thickness were measured on 2D CT scan and bone-block flushness was assessed using a straight-line and a circle. Glenoid surface area and coracoid graft area were also measured.

Results

Mean coracoid process length was 2.62cm (range, 2.17–3.05cm), width 1.52cm (range, 1.28–1.75cm) and thickness 1.16cm (range, 0.9–1.3cm). Mean preoperative glenoid area was 5.62 cm2 (range, 4.76–6.31cm2) and the articular area of the coracoid process was 2.78 cm2 (range, 2.43–3.27cm2). The coracoid graft thus increased glenoid area by a mean 49.2% (range, 41–53%). Axial CT slices systematically showed good bone-block positioning.

Discussion and conclusion

The congruent-arc technique can be performed entirely under arthroscopy, and provides anatomic glenoid reconstruction. It offers an option in case of severe inverted-pear glenoid bone defect.

Type of study

Prospective.

Level of evidence

III, case-control.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Latarjet, Arthroscopy, Congruent-arc, Inverted-pear glenoid, Shoulder instability


Mappa


© 2017  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 103 - N° 3

P. 441-446 - maggio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Surgical repair of massive rotator cuff tendon tears: Autologous quadriceps tendon graft versus arthroscopic repair
  • C. Tempelaere, P. Desmoineaux, F. Lespagnol, J. Pierrart, P. Beaufils, N. Pujol
| Articolo seguente Articolo seguente
  • Lasso plate – An original implant for fixation of type I and II Regan-Morrey coronoid fractures
  • P. Wang, Y. Zhuang, Z. Li, W. Wei, Y. Fu, X. Wei, K. Zhang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.