Abbonarsi

Poor outcomes of fusion with Trabecular Metal implants after failed total ankle replacement: Early results in 11 patients - 31/03/18

Doi : 10.1016/j.otsr.2017.11.022 
S. Aubret b, c, , L. Merlini b, M. Fessy a, b, J.-L. Besse a, b
a Laboratoire de biomécanique et mécanique des Chocs, IFSTTAR, LBMC UMR-T 9406, université Lyon 1, 69675 Bron cedex, France 
b Service de chirurgie orthopédique et traumatologique, centre hospitalier Lyon-Sud, hospices Civils de Lyon, 69495 Pierre-Bénite cedex, France 
c Service de chirurgie orthopédique et traumatologique, université Clermont Auvergne, CHU Clermont-Ferrand, 63000 Clermont-Ferrand, France 

Corresponding authorService de chirurgie orthopédique et traumatologique, université Clermont-Auvergne, CHU Clermont-Ferrand, 63000 Clermont-Ferrand, France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

One of the reasons for revision of total ankle replacement (TAR) implants is loosening due to subchondral cysts. Reconstruction and fusion of the ankle is often the first choice for revision procedures due to the large bone defects, which are typically filled with autograft and/or allograft. Filling the defect with a trabecular metal tantalum implant is a potential alternative given the biomechanical properties of this component.

Hypothesis

Using tantalum as a spacer provides primary stability and contributes to fusion of the ankle joint after removal of failed TAR implants.

Methods

Eleven patients underwent arthrodesis an average of 6.9 years after TAR. The mean height of the bone defect was 32mm. It was filled with a specially designed quadrangular implant (Trabecular Metal™, Zimmer/Biomet) combined with an iliac crest graft. Ten patients underwent tibio-talo-calcaneal (TTC) arthrodesis fixed with an angled retrograde nail and one patient underwent talocrural arthrodesis fixed with two plates (anterolateral and anteromedial). The clinical, functional (AOFAS and SF36 scores) and radiological (plain X-rays and CT scan) outcomes were determined.

Results

At a mean follow-up of 19.3 months, the mean total AOFAS score was 56 (21–78) and the mean SF36 score was 60.5 (19–84). One patient was lost to follow-up and four patients still had pain. The tantalum implant was integrated in six patients. Five patients achieved fusion of the subtalar joint and 8 achieved fusion of the talocrural joint. Three patients required surgical revision.

Discussion

Our hypothesis was not confirmed. The clinical outcomes after more than 1 year of follow-up are disappointing, as was the large number of nonunion cases and the lack of tantalum integration. These technical failures can be explained by insufficient construct stability and/or insufficient implant porosity.

Level of Evidence

IV (retrospective cohort study).

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total ankle replacement, Revision, Tantalum, Trabecular Metal, Ankle fusion


Mappa


© 2018  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 104 - N° 2

P. 231-237 - aprile 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Intraarticular synovial sarcoma of the knee rising from a lateral meniscus – a case report
  • M. Bergovec, M. Smerdelj, F. Bacan, S. Seiwerth, D. Herceg, M. Prutki
| Articolo seguente Articolo seguente
  • Sinus tarsi approach (STA) versus extensile lateral approach (ELA) for treatment of closed displaced intra-articular calcaneal fractures (DIACF): A meta-analysis
  • L. Bai, Y.-L. Hou, G.-H. Lin, X. Zhang, G.-Q. Liu, B. Yu

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.