Accuracy of patient-specific guided implantation of the glenoid component in reversed shoulder arthroplasty - 27/09/18

Doi : 10.1016/j.otsr.2018.01.010 
O. Verborgt a, b, f, , A.I. Hachem c, K. Eid d, K. Vuylsteke a, f, M. Ferrand e, P. Hardy e, 1
a Département de chirurgie orthopédique, AZ Monica, 20, Stevenslei, Anvers, Belgium 
b Faculté de médecine et des sciences de la santé, université d’Anvers, Anvers, Belgium 
c Département de chirurgie orthopédique et traumatologique, hôpital universitaire Bellvitge, Barcelone, Spain 
d Département de chirurgie orthopédique, Kantonsspital Baden, Baden, Switzerland 
e Département de chirurgie orthopédique et traumatologique, hôpital Ambroise-Paré, université Paris-Ouest, 92104 Boulogne-Billancourt, France 
f Fondation More, 20, Stevenslei, Anvers, Belgium 

Corresponding author at: Department of Orthopaedic Surgery, AZ Monica, Stevenslei 20, 2100 Antwerp, Belgium.Department of Orthopaedic Surgery, AZ Monica, Stevenslei 20Antwerp2100Belgium

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

The aim of this study was to assess the accuracy of patient-specific guided glenoid component implantation in reverse shoulder arthroplasty.

Materials and methods

32 reverse shoulder arthroplasties were done using preoperative 3D planning and 4 patient-specific guides to prepare the glenoid and position the glenoid component. Baseplate version, inclination and entry point as well as angulation of the screws were compared to the preoperative plan measured on CT by independent observers.

Results

The mean deviation in baseplate version from the preoperative plan was 4.4°+3.1° (range, 0.3°–13.7°), in baseplate inclination 5.0°+4.2° (range, 0.1° to 14.5°) and in baseplate entry point 2.4mm+1.4mm (range, 0.4° to 6.3°). The average screw superior-inferior angulation deviation for the superior screw was 2.8°+2.6° (range, 0.0°–10.1°) and 2.8+2.6° in the antero-posterior plane (range, 0.1°–11.6°). For the inferior screw the superior-inferior angle deviation was 5.3°+3.8° (range, 0.1°–15.2°); the antero-posterior angle deviation was 4.1°+3.1° (range, 0.0°–9.8°).

Conclusions

Patient-specific instrumentation (PSI) for the glenoid component in reverse shoulder arthroplasty allows the shoulder surgeon to accurately execute the preoperative 3D plan.

Level of evidence

Level 3.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Shoulder, Arthroplasty, Reverse, Glenoid, Patient-specific targeting guides


Mappa


© 2018  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 104 - N° 6

P. 767-772 - ottobre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Is reverse total shoulder arthroplasty more effective than hemiarthroplasty for treating displaced proximal humerus fractures in older adults? A systematic review and meta-analysis
  • David Gallinet, Xavier Ohl, Lauryl Decroocq, Choukry Dib, Philippe Valenti, Pascal Boileau, the French Society for Orthopaedic Surgery (SOFCOT) e
| Articolo seguente Articolo seguente
  • Reverse shoulder arthroplasty for proximal humerus fractures: Is the glenoid implant problematic?
  • Arthur Lignel, Julien Berhouet, Marc-Alexandre Loirat, Philippe Collin, Hervé Thomazeau, David Gallinet, Pascal Boileau, Luc Favard

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.