Abbonarsi

Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures - 27/09/18

Doi : 10.1016/j.otsr.2018.05.002 
Raffaele Mugnai a, , Luigi Tarallo a, Francesco Capra b, Fabio Catani a
a Orthopaedics and Traumatology Department, Modena University Hospital, Via Pietro Giardini, 1355, Baggiovara, 41126 Modena MO, Italy 
b Rimini, Italy 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates.

Hypothesis

Carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures.

Materials and Methods

Three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue.

Results

The mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (−16%) for the titanium plate. Statistical analysis between groups reported significant values (p<001) for all comparisons except for Hand Innovations vs. Zimmer bending stiffness post fatigue (p=.197).

Discussion

The significant higher load to failure of the titanium plate, makes it indicated for patients with higher functional requirements or at higher risk of trauma in the post-operative period. The CFR-PEEK plate showed material-specific disadvantages, represented by little tolerance to plastic deformation, and lower load to failure.

Level of evidence

N/A.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Distal radius, Plate, Bending stiffness, Load to failure, Biomechanical, Material


Mappa


© 2018  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 104 - N° 6

P. 877-882 - ottobre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Combined median and ulnar nerve palsy complicating distal radius fractures
  • Florence Dauzere, Stéphanie Delclaux, Thuy Trang Pham, Michel Rongières, Pierre Mansat
| Articolo seguente Articolo seguente
  • Double-tiered subchondral support fixation with optimal distal dorsal cortical distance using a variable-angle volar locking-plate system for distal radius fracture in the elderly
  • Sang Ki Lee, Young Sub Chun, Hyun Min Shin, Soo Min Kim, Won Sik Choy

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.