Abbonarsi

Can the Reamer/Irrigator/Aspirator System replace anterior iliac crest grafting when treating long bone nonunion? - 21/04/19

Doi : 10.1016/j.otsr.2018.12.011 
Marie Le Baron a, , Jean-Philippe Vivona b, Pascal Maman a, Richard Volpi a, Xavier Flecher a
a Institut du mouvement et de l’appareil locomoteur, CHU Marseille Nord, chemin des Bourrely, 13015 Marseille, France 
b Polyclinique du Parc-Rambot – Provençale, 67, cours Gambetta, 13100 Aix-en-Provence, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Autologous bone graft is the gold standard for filling bone defects associated with diaphyseal nonunions. It is typically harvested from the anterior iliac crest (AIC) despite the high complication rate. The Reamer/Irrigator/Aspirator System (RIA) was developed to recover the reaming aspirate and use it as autograft. Initially described for harvesting bone from the femur, the bone volume available is similar to the AIC site; however, its use directly at nonunion sites has been studied very little.

Hypotheses

Compared to AIC harvesting, RIA at a non-union site will result in (1) sufficient bone volume, (2) similar time to union and union rate, (3) lower morbidity.

Results

Two groups of patients received an autograft for aseptic nonunion of the tibia or femur for a bone defect up to 2cm: the RIA group (n=30) was followed prospectively and received an autograft by RIA while the AIC group (n=29) was reviewed retrospectively and received an autograft by AIC. We compared the time to union and union rate, operative time, intake of analgesics, duration of hospital stay and complication rate between groups. The RIA provided sufficient bone, 60cm3 on average in a reliable manner. The union rate was similar between groups: 90% (RIA) and 89.7% (CIA) (p=0.965), while the time to union was shorter in the RIA group (8.63±1.47months vs. 10.08±1.7 months) (p=0.006). The operative time (p<0.0001), analgesic intake (p=0.013), length of stay (p<0.0001) and immediate complication rate (p=0.0195) were higher in the AIC group.

Discussion

For the treatment of aseptic long bone nonunion, autograft harvested by the RIA from the nonunion site results in similar union rate and time to union as AIC grafts without additional complications.

Level of evidence

IV, comparative retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Nonunion, Bone grafting, Tibia fracture, Femur fracture


Mappa


© 2019  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 105 - N° 3

P. 529-533 - maggio 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • Predictors of mechanical complications after intramedullary nailing of tibial fractures
  • Julie Manon, Christine Detrembleur, Simon Van de Veyver, Karim Tribak, Olivier Cornu, Dan Putineanu
| Articolo seguente Articolo seguente
  • Induced membrane technique in the treatment of infectious bone defect: A clinical analysis
  • Jianbing Wang, Qudong Yin, Sanjun Gu, Yongwei Wu, Yongjun Rui

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.