Abbonarsi

Detection of dorsal screw penetration during volar plating of the distal radius fractures: A comparison of different fluoroscopic views and screw sizes - 10/04/20

Doi : 10.1016/j.otsr.2019.11.011 
Yun-Qiang Zhuang a, Jia-Yu Zhang b, Xian-Bin Yu b, Hua Chen b, Yao-Sen Wu b, , Liao-Jun Sun b,
a Department of Orthopaedic Surgery, Ningbo No. 6 Hospital, Ningbo, Zhejiang, China 
b Department of Orthopaedic Surgery, the Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, China 

Corresponding author.⁎⁎Co-corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Objective

The objective of this study was to compare different screw lengths combined with different fluoroscopic views to detect intraoperative dorsal screw penetration in distal radius fractures treated with volar locked plating.

Material and methods

From April 2014 to October 2018, one hundred and eighty patients were included. We divided the patients into four groups. Intraoperative AP and lateral views were taken and sizes of the screws were chosen based on actual measurement (Group A, 45 patients). AP, lateral and tangential views were taken and sizes of the screws were also chosen based on actual measurement (Group B, 45 patients). Intraoperative AP and lateral views were taken and the selected screws were 2mm shorter than actual measurement (Group C, 45 patients). AP, lateral and tangential views were taken and the selected screws were 2mm shorter than actual measurement (Group D, 45 patients). Prominent screws were changed intraoperatively according to each view. A computed tomography (CT) was taken postoperatively to identify residual prominent screws.

Results

The number of dorsally prominent screws exceeding 1mm was 6 of 301 in Group A (2.0%), 15 of 290 (5.2%) in Group B, 2 of 289 in Group C (0.7%), and 2 of 282 (0.7%) in Group D. All these prominent screws (25 screws) were exchanged for shorter screws during surgery. Group A and Group B had significant difference in detecting intraoperative dorsal screw penetration (p<0.05). Group C and Group D had no significant difference in detecting intraoperative dorsal screw penetration (p>0.05). Postoperative CT identified 12 additional prominent screws with1mm dorsal penetration in Group A, 2 screws in Group B, 1 screw in Group C and 0 screw in Group B respectively. Significant difference was found between Group A and Group B of CT results (p<0.05) while no statistical difference was found between Group C and Group D of CT results (p>0.05).

Discussions

Tangential view helped identify screw penetration. If tangential view was not available intraoperatively, screw penetration could also be avoided by downsizing the distal locking screw by 2mm shorter than actual measurement.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Distal radius fractures, Volar plate, Screw penetration, Tangential view


Mappa


© 2019  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 106 - N° 2

P. 377-380 - aprile 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Treatment of supracondylar humeral non-union by bone autograft and Hoffmann II external fixation
  • Pieter Antoine Pierreux, Fabian Moungondo, Frédéric Arthur Schuind
| Articolo seguente Articolo seguente
  • Comment on “Surgical hip dislocation is more powerful than arthroscopy for achieving high degrees of acetabular correction in pincer type impingement” of Ahmad SS, Heilgemeir M, Anwander H, Beck M. Published in Orthop Traumatol Surg Res 2019;105:1339–44
  • Jiangen Lian, Junfeng Lian, Mingjin Zhong

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.