Abbonarsi

Validation of a novel finite-element model for evaluating patellofemoral forces and stress during squatting after posterior-stabilized total knee arthroplasty - 19/08/23

Doi : 10.1016/j.otsr.2022.103519 
Salah Mebarki a, Franck Jourdan a, François Canovas b, Etienne Malachanne a, Louis Dagneaux a, b,
a Laboratoire de mécanique et génie civil (LMGC), CNRS, Montpellier University of Excellence (MUSE), 860, rue de St-Priest, 34090 Montpellier, France 
b Department of Orthopaedic Surgery, Lower limb Surgery Unit, Lapeyronie University Hospital, Montpellier University, 371, avenue Gaston-Giraud, 34295 Montpellier, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Several studies have documented the relationship between patellofemoral pain and patient dissatisfaction after total knee arthroplasty (TKA). However, few computer simulations have been designed to evaluate the patellofemoral joint during flexion. The aim of this study was to validate a new computational simulation, driven by forces and moments, and to analyze patellofemoral reaction forces and stress under squat loading conditions after TKA implantation.

Hypothesis

This computational simulation of a squat using a model driven by forces and moments is comparable to in vitro and in silico data from the literature.

Material and methods

We developed a finite element model of the lower limb after implantation of a fixed-bearing posterior-stabilized TKA. To simulate squat loading conditions when standing on both legs, an initial load of 130N was applied to the center of the femoral head. Quadriceps force, patellofemoral contact force and Von Mises stress on the patellar implant, tibiofemoral contact forces and pressure on the tibial insert, and post-cam contact force were evaluated from 0° to 100° of knee flexion.

Results

Quadriceps force increased during flexion, up to 6 times the applied load. Von Mises stress on patellar implant increased up to 16MPa at 100° flexion. Tibiofemoral contact forces increased up to 415 N medially and 339 N laterally, with 64% distributed medially on the tibial insert. Post-cam contact started slightly before 70° of flexion.

Discussion

In this simulation, tibiofemoral, patellofemoral and post-cam contact forces, and pressure distribution on the tibial insert were consistent with various published studies. This agreement suggests that computational simulation driven by forces and moments can reproduce squat loading conditions during knee flexion after TKA, without experimental kinematic data used to drive the simulation.

Conclusion

This study represents an initial step towards validating tibiofemoral and patellofemoral mechanical behavior under squat conditions, from this computational simulation driven by forces and moments. This model will help us better understand the influence of various implantation techniques on patellofemoral forces and stress during flexion.

Level of evidence

IV, biomechanical computational study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Computational model, Biomechanics, Knee replacement, Alignment, Patellofemoral

Abbreviations : TKA, FEM, CAD, N, MPa


Mappa


© 2022  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 109 - N° 5

Articolo 103519- settembre 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • Patellar medial-lateral position can be used to correct the effect of leg rotation on preoperative planning in total knee arthroplasty for varus knees
  • Shinichiro Nakamura, Shota Takemoto, Shinichi Kuriyama, Kohei Nishitani, Hiromu Ito, Mutsumi Watanabe, Young Dong Song, Shuichi Matsuda
| Articolo seguente Articolo seguente
  • Preoperative flexion contracture does not affect outcome in total knee arthroplasty: A case-control study of 2,634 TKAs
  • Andrea Fernandez, Elliot Sappey-Marinier, Jobe Shatrov, Cécile Batailler, Philippe Neyret, Denis Huten, Elvire Servien, Sébastien Lustig

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.