Abstract

Introduction

Femoral megaprostheses are used for bone reconstruction surgery in patients with local tumors or who require multiple revisions. Patient reported outcome measures (PROMs) provide a subjective result and, like patient satisfaction, have become an integral part of the outcomes in orthopedics. However, the threshold of satisfaction (PASS: Patient Acceptable Symptom State) has not yet been defined in a French population after this type of arthroplasty. This led us to carry out a retrospective study on a population of patients who received a femoral reconstruction megaprosthesis in order to 1) define the PASS for the Harris Hip Score (HHS), Knee Society Score (KSS) and the Musculoskeletal Tumor Society score (MSTS), 2) study the complications.

Hypothesis

The PASS threshold for proximal femur and distal femur reconstruction prothesis for the HHS and the KSS, respectively, will be lower than the threshold for these same scores for primary arthroplasty.

Materials and methods

Forty-four patients who were operated on between 2009 and 2020 were included: 23 received a proximal femur prosthesis and 21 received a distal femur prosthesis. The PASS threshold was defined using an anchoring strategy by analyzing ROC curves for the HSS for the proximal femur, KSS for the distal femur and the MSTS for all the prostheses. Complications were classified according to Henderson.

Results

The mean follow-up was 4.5 ± 3.6 (1–12.5) years. The PASS threshold was 47.5 (area under curve (AUC) 0.71 (0.45–0.97)) for the HHS, 69.5 (AUC 0.97 (0.92–1.0)) for the KSS knee and 62.5 (AUC 0.81 (0.61–0.99)) for the KSS function. Thirteen patients (29%) had complications, nine of whom required another surgery (20%). The most frequent were Henderson type 1 (soft tissue lesions, n = 5/44 [11%]) and type 2 (loosening, n = 5/44 [11%]) There was no relationship between satisfaction and postoperative complications (p = 0.071).

Discussion

Most of the patients who undergo femoral resection and reconstruction (59%) are satisfied with their function, albeit reduced, despite a high complication rate (29%). Our hypothesis is confirmed for the PASS threshold for the HHS (47.5 versus 93) and the KSS knee and function (69.5 and 62.5 versus 85.5 and 72.5).

Level of evidence

IV; retrospective observational single-center study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Reconstruction prothesis, Proximal femur, Distal femur, Satisfaction, PASS


Mappa


© 2024  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 110 - N° 7

Articolo 103931- novembre 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • Simple Hip Value: a simple score to evaluate Hip function
  • Alix Addi, Tristan Duguay, Eugenie Valentin, Philippe Anract, Alexandre Hardy
| Articolo seguente Articolo seguente
  • Hip and knee arthroplasty in one surgical session: early morbi-mortality study
  • Henri Favreau, Jean-Luc Raynier, Thomas Rousseau, Sébastien Lustig, François Bonnomet, Christophe Trojani

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.