Abbonarsi

Can fluoroscopy radiation exposure be measured in minimally invasive trauma surgery? - 14/10/11

Doi : 10.1016/j.otsr.2011.03.024 
A. Roux a, , N. Bronsard a, N. Blanchet b, F. de Peretti a
a Traumatology and Orthopedics Department, Saint-Roch Hospital, Nice University Hospital Center, 5, rue Pierre-Dévoluy, 06000 Nice, France 
b Occupational Medicine Department, Saint-Roch Hospital, Nice University Hospital Center, 5, rue Pierre-Dévoluy, 06000 Nice, France 

Corresponding author. Tel.: +33 4 92 03 33 48.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Repeated use of X-rays in orthopedic surgery poses the problem of irradiation of patient and caregivers. Seven common minimally invasive bone trauma surgical procedures requiring image intensifier use were investigated: percutaneous K-wire fixation of the wrist, minimally invasive fixation plating of the wrist, percutaneous intramedullary nailing of the tibia and of the femur, short and long trochanteric nail fixation of trochanteric and sub-trochanteric fracture, and percutaneous fixation of thoracolumbar fracture. The study analyzed three parameters: dose area product (DAP), radiation duration, and skin entrance dose (SED). Data were collected from 15 successive implementations of each procedure. The aim of the study was to establish a database for this kind of bone trauma surgery and a hierarchy of the X-ray doses delivered. Percutaneous spinal osteosynthesis involved the highest dose, followed in decreasing order by long trochanteric nailing, femoral nailing, short trochanteric nailing, tibial nailing, wrist K-wire fixation and frontal wrist plate osteosynthesis. One short trochanteric nail procedure delivered the same DAP as 13 wrist K-wire fixation procedures, and one spinal osteosynthesis was equivalent to 13 short trochanteric nail or 174 wrist K-wire procedures. The anatomic area X-rayed appeared to be the main radiation dose factor. A database was established, but actual patient and staff radiation levels remained unknown.

Level of evidence

Level III, case-control study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Radiation, Osteosynthesis, Orthopedic, Radiation safety, Radiation exposure


Mappa


© 2011  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 97 - N° 6

P. 662-667 - ottobre 2011 Ritorno al numero
Articolo precedente Articolo precedente
  • Fixed-bearing unicompartmental knee arthroplasty. Patients’ selection and operative technique
  • G. Deschamps, C. Chol
| Articolo seguente Articolo seguente
  • Minimally-invasive fixation of distal extra-articular femur fractures with locking plates: Limitations and failures
  • M. Ehlinger, P. Adam, Y. Arlettaz, B.K. Moor, A. DiMarco, D. Brinkert, F. Bonnomet

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.