Abbonarsi

Proximal femoral nail antirotation (PFN-ATM) fixation of extra-capsular proximal femoral fractures in the elderly: Retrospective study in 102 patients - 25/04/12

Doi : 10.1016/j.otsr.2011.11.006 
E. Soucanye de Landevoisin , A. Bertani, P. Candoni, C. Charpail, E. Demortiere
Department of Orthopaedic Surgery and Traumatology, Laveran Military Teaching Hospital, 13, boulevard Laveran, 13013 Marseille, France 

Corresponding author. Tel.: +33 4 91 61 72 26; fax: +33 4 91 61 75 10.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Background

The best surgical strategy for extra-capsular proximal femoral fractures (PFFs) is controversial in the elderly. Poor bone quality and neck screw instability can adversely affect the results with currently available fixation devices, which predominantly consist in dynamic hip screw-plates and proximal reconstruction nails.

Hypothesis

The helical blade of the proximal femoral nail antirotation (PFN-A™) achieves better cancellous bone compaction in the femoral neck, thereby decreasing the risk of secondary displacement.

Materials and Methods

We retrospectively reviewed consecutive cases of PFN-A™ fixation performed between 2006 and 2008 in 102 patients (75 females and 27 males) with a mean age of 84.9±9.5 years (range, 70–100 years). Functional outcomes were assessed using the Parker Mobility Score.

Results

Mean follow-up in the 102 patients was 21.3±17.5 months (4–51 months). Fracture distribution in the AO classification scheme was A1, n=45; A2, n=41; and A3, n=16. At last follow-up, Parker Mobility Score values in the 65 survivors were 0–3, n=35; 4–6, n=11; and 7–9, n=19. Fracture union was consistently achieved, after a mean of 10.3±3 weeks. Blade back-out allowed by the device design occurred in 16 (15.7%) patients but caused pain due to screw impingement on the fascia lata in only five patients (of whom two underwent reoperation). Cephalic blade cut-out was noted in three (2.9%) patients, of whom one required reoperation because of acetabular penetration. Two hardware-related fractures were recorded.

Discussion

The new PFN-A™ device ensures reliable fixation with low mechanical complication rates. Although our data do not constitute proof that a helical blade is superior over a neck screw, they suggest a decreased rate of construct failure and may serve as a basis for a comparative study.

Level of evidence

Level IV, retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Intertrochanteric hip fracture, PFN-A™ fixation, Extra-capsular fracture, Proximal femoral helical blade


Mappa


© 2012  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 98 - N° 3

P. 288-295 - maggio 2012 Ritorno al numero
Articolo precedente Articolo precedente
  • Retrieval analysis of squeaking ceramic implants: Are there related specific features?
  • C. Chevillotte, R.T. Trousdale, K.-N. An, D. Padgett, T. Wright
| Articolo seguente Articolo seguente
  • Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation
  • P. Adam, R. Philippe, M. Ehlinger, O. Roche, F. Bonnomet, D. Molé, M.-H. Fessy, the French Society of Orthopaedic Surgery and Traumatology (SoFCOT) SoFCOT, 56, rue Boissonade, 75014 Paris, France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.