Abbonarsi

Tibial plateau fractures: Reproducibility of three classifications (Schatzker, AO, Duparc) and a revised Duparc classification - 24/10/13

Doi : 10.1016/j.otsr.2013.06.007 
T. Gicquel a, N. Najihi a, T. Vendeuvre b, S. Teyssedou b, L.-E. Gayet b, D. Huten a,
a Service d’orthopédie-traumatologie, hôpital Pontchaillou, 2, rue Le Guilloux, 35033 Rennes, France 
b Service d’orthopédie-traumatologie, CHU de Poitiers, 86000 Poitiers, France 

Corresponding author. Tel.: +33 02 99 28 43 21.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Introduction

Since the reproducibility of the Schatzker and AO tibial plateau fracture classification systems has already been assessed, the goal of this study was to evaluate the Duparc classification system and compare it to the other two.

Hypotheses

CT scan is better than X-rays for analyzing and classifying tibial plateau fractures. The Duparc classification system is more effective than the other two systems but could be improved by adding elements of each.

Materials and methods

Six observers analyzed images from 50 fractures and then classified them. Each fracture was evaluated on X-rays. Two weeks later, these same fractures were evaluated on X-rays and CT scans. The same process was repeated four weeks later. The Kappa coefficient (κ) was used to measure agreement and contingency tables were built.

Results

The interobserver reproducibility for the X-ray analysis was poor for the Duparc and AO classifications (κDuparc=0.365; κAO=0.357) and average for the Schatzker classification (κSchatzker=0.404). The reproducibility was improved overall when CT scans were also analyzed (κDuparc=0.474; κAO=0.479; κSchatzker=0.476). A significantly greater number of fractures could not be classified in the Schatzker system than in the others (14.3% versus 2% for Duparc and 7.33% for AO). Review of the contingency tables revealed that the Schatzker and AO classification systems did not take certain fracture types into account. Seventy-one percent (71%) of the lateral unicondylar split fractures were found to be combined fractures when CT scan analysis was added.

Discussion

Our results showed CT scan to be better at analyzing and classifying fractures. We also found the Duparc classification to be advantageous because it allowed more fractures to be classified than in other classification systems, while having similar reproducibility. Based on our study findings, the Duparc classification was revised by adding elements of the other two. We propose using the modified Duparc classification system to analyze tibial plateau fractures going forward.

Level of evidence

Level IV. Retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Tibial plateau fractures, Classification system, Reproducibility, CT scan


Mappa


© 2013  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 7

P. 805-816 - novembre 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Distal targeting device for long Gamma nail®. Monocentric observational study
  • M. Ehlinger, G. Dillman, J. Czekaj, P. Adam, G. Taglang, D. Brinkert, B. Schenck, A. Di Marco, F. Bonnomet
| Articolo seguente Articolo seguente
  • Distal quadricepsplasty in children: 88 cases of retractile fibrosis following intramuscular injections treated in Benin
  • M.-A. Fiogbe, A.S. Gbenou, E.R. Magnidet, O. Biaou

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.