Abstract

Background

The effect of hydroxyapatite (HA) coating on the fixation of a cementless femoral stem is discussed, in particular in cases of primary fixation with geometrically stable components. Therefore, we performed a comparative retrospective study of a series of Alloclassic-SL™ stems to: 1) present the long-term results and 2) evaluate the contribution, if any, of proximal HA coating.

Hypotheses

Long-term cementless press-fit (“flat wedge-shaped”) fixation is reliable and HA coating only improves the radiological results of the proximal bone-prosthesis interface.

Materials and Methods

One hundred and ninety-eight Alloclassic total hip arthroplasties were performed in 179 patients, mean age 66 years old (22–85), including 105 with proximal HA coating and 93 with the original grit-blast coating. One hundred and ninety-three hips were analyzed after a mean follow-up of 9.8 years (1–24 years).

Results

Results were excellent or good in 184 hips (95%) with no significant difference between the 2 groups (Merle d’Aubigné16 for 89/92 (98%) without HA compared to 95/101 (94%) with HA P=0.59). Radiographic signs of stable osseointegration were observed in 173 hips (90% of the cases). HA coating significantly improved the radiographic results of the proximal bone-implant interface: (42/92 (46%) of the stems without HA had proximal radiolucencies in zones 1 and 7 compared to 4/101 (4%) with HA (P=0.0001)). Polyethylene wear>0.1 mm/year was observed in 6 hips (3%) including 1/101 (1%) in the group with HA versus 5/92 (5.4%) without HA (P=0.17). One intra-operative femoral fracture occurred and there were 9 dislocations in the first 3 postoperative months (4.5%). The main cause of revision surgery was recurrent dislocation (11/17 cases). The “revision per-100 observed-femoral component years” was 0.10 in both groups and survival for aseptic loosening of the stem was 100% (95% CI=73.2% to 100%) at 20 years.

Conclusion

This study shows that secondary fixation by osseointegration of a straight standard grit-blasted titanium alloy non-anatomical implant is reliable. Possible proximal fibrous encapsulation, which is reduced by HA coating, but especially conventional polyethylene wear, were the main limitations of this system.

Level of evidence

III retrospective case-control study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Cementless stem, Alloclassic system, Total hip arthroplasty, Hydroxyapatite


Mappa


© 2014  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.