S'abonner

The Nice knot as an improvement on current knot options: A mechanical analysis - 25/04/16

Doi : 10.1016/j.otsr.2016.01.005 
P. Collin a, E. Laubster a, P.J. Denard b, c, F.A. Akuè a, A. Lädermann d, e, f,
a Saint-Grégoire Private Hospital Center, boulevard Boutière 6, 35768 Saint-Grégoire cedex, France 
b Southern Oregon Orthopedics, Medford, Oregon, USA 
c Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, Oregon, USA 
d Division of Orthopaedics and Trauma Surgery, La Tour Hospital, rue J.-D.-Maillard 3, 1217 Meyrin, Switzerland 
e Faculty of Medicine, University of Geneva, rue Michel-Servet 1, 1211 Geneva 4, Switzerland 
f Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, rue Gabrielle-Perret-Gentil 4, 1211 Geneva 14, Switzerland 

Corresponding author. Tel.: +41 22 719 75 55; Fax: +41 22 719 60 77.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

There is currently a wide range of suture knots used in rotator cuff repair. The purpose of this study was to compare a new type of self-locking sliding knot called the Nice knot to the self-locking and sliding Nicky's knot.

Methods

Nice knots and Nicky's knots were tied and subjected to mechanical testing including a pure traction stress and a series of dynamic stresses. Both knots were tied using standard braided suture and reinforced braided suture. The responses to these stresses were measured in the amount of elongation of the knot, maximum effort needed for failure, stiffness of construct and dynamic stiffness.

Results

With both knots the standard suture had a lower amount of elongation during the dynamic tests than the reinforced braided suture. The reinforced braided suture showed superior results during maximal effort in the pure traction tests. An increased failure rate occurred due to elongation when a dynamic stress was applied to the reinforced suture in both knot types. During dynamic testing the Nice knot showed a decrease in the amount of elongation (P<0.001).

Conclusions

The Nice knot provides a sliding locking knot option which can decrease the risk of elongation during dynamic stress.

Level of evidence

Basic Science Study, Biomechanical Study.

Le texte complet de cet article est disponible en PDF.

Keywords : Shoulder surgery, Rotator cuff repair, Nice knot, Nicky's knot, Suture, Ethibond®, Ultrabraid, Mechanical testing, Biomechanical study, Arthroscopy


Plan


© 2016  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° 3

P. 293-296 - mai 2016 Retour au numéro
Article précédent Article précédent
  • Comparison of intramedullary fibular allograft with locking compression plate versus shoulder hemi-arthroplasty for repair of osteoporotic four-part proximal humerus fracture: Consecutive, prospective, controlled, and comparative study
  • H. Chen, X. Ji, Y. Gao, L. Zhang, Q. Zhang, X. Liang, P. Tang
| Article suivant Article suivant
  • Revisions of total shoulder arthroplasty: Clinical results and complications of various modalities
  • M. Antoni, M. Barthoulot, J.F. Kempf, P. Clavert

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.