Abstract

Introduction

To reduce the size of the surgical incision, modular mini-keel tibial components have been developed with or without extensions for the Nexgen™ MIS Tibial Component. Although a smaller component could theoretically result in defective fixation, this has never been evaluated in a large comparative series. Thus, we performed the following case control study to: (1) evaluate intermediate-term survival of a modular “mini-keel” tibial component compared to a reference standard keel component from the same line of products (Nexgen LPS-Flex Tibial Component, Zimmer); (2) to identify any eventual associated factors if the frequency of loosening was increased.

Hypothesis

The rate of revision for aseptic tibial loosening is comparable for both components.

Materials and methods

This comparative, retrospective, single center series of 459 consecutive total knee arthroplasties (TKA) was performed between 2007 and 2010: with 212 modular “mini-keel” (MK) tibial components and 247 “standard” (S) components. Survival, rate of revision for aseptic tibial loosening and identification of a radiolucent line were analyzed at the final follow-up.

Results

After a median follow-up of 5years, the rate of revision for tibial aseptic loosing was significantly higher in the MK group with 12 cases (5.7%) and 4 cases in the S group (1.6%) (P=0.036). The use of the MK component appears to be a prognostic factor for surgical revision (hazard ratio=3.86 (1.23–11.88), P=0.02) but not for the development of a radiolucent line (HR=1.75 (0.9–3.4), P=0.097). The mean delay before revision was 38months (8–64) in the MK group and 15.2months (8–22) in the S group (P=0.006). Individual factors, such as gender, body mass index (BMI) and pre- or postoperative alignment were not prognostic factors for revision or radiolucent lines.

Conclusion

The modular “mini-keel” tibial component was associated with a greater risk of revision for tibial component loosening.

Level of evidence

Case control study, III.

Le texte complet de cet article est disponible en PDF.

Keywords : Aseptic loosenig, Total knee arthroplasty, MIS tibial component, Modular tibial component, Mini-keel


Plan


© 2016  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° 5

P. 611-617 - septembre 2016 Retour au numéro
Article précédent Article précédent
  • Medial patellofemoral ligament reconstruction for patellar instability following total knee arthroplasty: A review of 6 cases
  • A. Lamotte, T. Neri, A. Kawaye, B. Boyer, F. Farizon, R. Philippot
| Article suivant Article suivant
  • Rare ACL enthesis tears treated by suture in children. A report of 14 cases after a mean 15 years follow-up
  • P.-M. Xavier, J. Fournier, B. de Courtivron, F. Bergerault, C. Bonnard

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.