S'abonner

Does measuring the range of motion of the hip and knee add to the assessment of disability in people undergoing joint replacement? - 18/02/14

Doi : 10.1016/j.otsr.2013.09.016 
V. Wylde a, E. Lenguerrand a, , L. Brunton a, P. Dieppe b, R. Gooberman-Hill a, C. Mann c, A.W. Blom a
a Musculoskeletal Research Unit, School of Clinical Sciences, University of Bristol, Avon Orthopaedic Centre, Southmead Hospital, Bristol, BS10 5NB, United Kingdom 
b Peninsula Medical School, Universities of Exeter and Plymouth, Plymouth, PL6 8BU, United Kingdom 
c Musculoskeletal Research Unit, North Bristol NHS Trust, Avon Orthopaedic Centre, Southmead Hospital, Bristol, BS10 5NB, United Kingdom 

Corresponding author. Tel.: +44 0117 323 5906.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 18 February 2014
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background and hypothesis

Range of motion (ROM) is a core component of some commonly used measures of disability, such as the American Knee Society Score and Harris Hip Score. However, the relationship between ROM and function is contested. The aim of this cross-sectional analysis was to investigate the relationship between pre-operative range of motion (ROM) and disability in patients undergoing hip and knee joint replacement.

Patients and methods

Two hundred and forty-nine patients recorded on NHS records as listed for joint replacement completed a range of measures prior to surgery. Pre-operative hip or knee ROM was measured by a trained research nurse using a hand-held goniometer. Joint pain severity was assessed using the WOMAC Pain Scale. Self-report activity limitations and participation restrictions were measured with the WOMAC Function Scale and the Aberdeen Impairment, Activity Limitation and Participation Restriction Measure. Observed activity limitations were assessed through three performance tests: 20-metre timed walk, sit-to-stand-to-sit, and 20-cm step tests.

Results

Pre-operative hip and knee ROM correlated weakly with self-report activity limitations (0.11 to 0.43), observed activity limitations (0.09 to 0.39) and self-report participation restrictions (−0.32 to 0.06). In comparison to ROM, correlations between joint pain and self-report activity limitations and participation restrictions were consistently moderate-high (−0.53 to 0.80). However, patients with restricted knee joint flexion (<110°) had significantly worse pain, activity limitations and participation restrictions than patients with non-restricted flexion (≥110°). Patients with restricted hip joint flexion (<95°) had greater activity limitations on some measures than patients with non-restricted flexion (>95°).

Discussion

This study suggests that modest restrictions of ROM are of little relevance to functional ability but that a certain amount of flexion is required for adequate function. We recommend that ROM is not the best means of assessing patients’ disability prior to surgery.

Level of evidence

III – cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Arthroplasty, Replacement, Disability evaluation, Range of motion, Pain


Plan


© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.