S'abonner

042 - 3D fluorescence imaging of drug delivery for lung cancer therapy - 05/12/08

Doi : RMR-11-2008-25-9-0761-8425-101019-200810907 

V. Josserand [1 et 2],

M.  Guidetti [1 et 2],

A. Koenig [3],

L. Hervé [3],

J. Boutet [3],

M.  Berger [3],

G. Gonon [3],

P.  Peltier [3],

P. Rizo [3],

J.-L. Coll [1 et 2]

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Introduction: Defining appropriated models of lung tumours in mice that are similar in morphology, histopathology and molecular characteristics to human adenocarcinomas, and scaling down imaging methods to feet the small size of rodents are of the outmost importance for the pre-clinical validation of new treatments, identification of markers as well as to understand the sequences of molecular events leading to lung tumours formation.

High-resolution microtomography (micro-CT) as well as 1.5 T or more importantly 4.7 T MRI are the more commonly used methods to imaging lung tumour growth in animal models. Nonetheless, these methods require expensive machines, and are providing anatomical information mainly.

Near infrared fluorescence (NIRF) is commonly used in a Reflectance mode (2D), but the strong reflection of incident light and autofluorescence of the skin affects the sensitivity, especially in deep and absorbing tissues like lung, spleen or liver.

Methods: We developed a fluorescence diffuse optical tomograph (fDOT) which allows fluorescence imaging even in highly attenuating and heterogeneous regions like lungs, by correcting the light propagation model from optical heterogeneities by using the transmitted excitation light measurements. It allows non-contact measurements and does not require animal immersion in an optical adaptation liquid. We used a tumour-targeted NIR probe which has been demonstrated to recognize integrin vß3, a receptor over- expressed on the surface of neo-angiogenic endothelial cells.

Results: After intravenous injection of the probe to the mouse, the system records the outgoing transmitted and fluorescence light, then reconstructs the 3D fluorescence distribution resulting from the accumulation of the probe into cancerous nodules.

Conclusions: Whereas no significant evolution were noticed using the 2D fluorescence reflectance imaging confirming that it is not adequate for such analyzes, by using the 3D imaging system, we were able to do the longitudinal follow up of lung tumour development in live animals.




© 2008 Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 25 - N° 9

P. 1175 - novembre 2008 Retour au numéro
Article précédent Article précédent
  • 041 - Vectorization of nanoparticles by human mesenchymal stem cells for diagnosis and therapy in cancer: project of evaluation by in vivo molecular imaging
  • C. Rome, M. Keramidas, F. De Fraipont, MJ. Richard, E. Barbier, C. Remy, J.-L. Coll
| Article suivant Article suivant
  • 043 - α3 integrin/FGF-2 expression profile: signature of local progression after chemo- radiotherapy for patients with NSCLC
  • C. Massabeau, I. Rouquette, V. Cances-Lauwers, C. Toulas, J.-M. Bachaud5, E. Moyal, J. Mazieres

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.