S'abonner

Implantation de pacemaker et de défibrillateurs cardiaques sous ticagrelor : à propos de 20 patients - 29/10/16

Doi : 10.1016/j.ancard.2016.09.008 
W. Amara a, , S. Naccache a, C. Akret b, S. Cheggour c, S. M’Zoughi c, G. Galuscan d, A. Dompnier b
a Unité de rythmologie, GHI Le Raincy-Montfermeil, 10, rue du Général-Leclerc, 93370 Montfermeil, France 
b Centre hospitalier Annecy-Genevois, 1, avenue de l’Hôpital, 74370 Epagny Metz-Tessy, France 
c Centre hospitalier d’Avignon, 305, rue Raoul-Follereau, 84000 Avignon, France 
d Centre hospitalier André-Mignot, 177, rue de Versailles, 78150 Le Chesnay, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 4
Iconographies 1
Vidéos 0
Autres 0

Résumé

Introduction

La gestion du traitement antiagrégant au moment de l’implantation de dispositifs intracardiaques reste controversée. Cette étude vise à évaluer le risque de complications hémorragiques chez les patients implantés de prothèses cardiaques sous ticagrelor.

Méthodes

Nous avons effectué une étude multicentrique (n=4), rétrospective, du mois de janvier 2015 et jusqu’à janvier 2016. Ont été inclus tous les patients ayant eu une implantation de stimulateur cardiaque, de défibrillateur automatique implantable (DAI) ou de changement de boîtier sous ticagrelor. Nous rapportons les complications postopératoires hémorragiques à 1 mois. Une complication hémorragique significative a été définie par un hématome de loge nécessitant une évacuation chirurgicale ou une prolongation de l’hospitalisation, un hémothorax, un épanchement péricardique, ou une tamponnade.

Résultats

Au total 20 patients ont été inclus. L’âge moyen des patients était de 65±9ans, 95 % étaient des hommes, 25 % des patients étaient diabétiques, 55 % étaient hypertendus et 50 % présentaient des antécédents d’insuffisance cardiaque. Tous les patients avaient des antécédents de syndrome coronarien aigu (6 [4–26] mois avant la procédure). La majorité des dispositifs implantés étaient des DAI (17, 85 %) avec 5 mono chambre, 4 double chambre et 9 triple chambre. La voie veineuse sous-clavière a été utilisée chez 9 patients. La durée moyenne de la procédure était de 60minutes. Un saignement per-procédural a été décrit et était secondaire à une pression veineuse élevée au moment de la procédure, sans être compliqué d’un hématome postopératoire. Un seul hématome de la loge a été constaté. L’approche sous-clavière a été utilisée pour les 2 patients. Aucune transfusion sanguine n’a été nécessaire pour les 2 cas.

Conclusion

Le traitement par ticagrelor au cours des procédures d’implantation de dispositifs électroniques intracardiaques, ne semble pas être associé à un risque accru de saignement. Dans notre étude, 2 patients ont eu des complications hémorragiques non significatives.

Le texte complet de cet article est disponible en PDF.

Abstract

Introduction

Management of antiplatelet therapy at the time of device implantation remains controversial. This study aimed to assess the risk of bleeding complications in patients receiving ticagrelor at the time of cardiac device surgery.

Methods

We performed a multicentre (n=4), retrospective study from January 2015 to January 2016. The survey included all patients (pts) treated with ticagrelor before undergoing pacemaker, implantable cardioverter-defibrillator (ICD) implantation or generator replacement. We report hemorrhagic post-procedural complications at 1 month. A significant bleeding complication was defined as pocket hematoma requiring a surgical evacuation or prolonged hospitalization, hemothorax, pericardial effusion, or tamponade.

Results

A total of 20 patients underwent a permanent pacemaker or ICD implantation while taking a combination of antipatelet therapy with ticagrelor and aspirin. The mean age of the patients was 65±9 years, 95% were male, 25% of patients were diabetics, 55% had hypertension and 50% presented a history of heart failure. All the patients had a history of acute coronary syndrome [6 (4–26) months before the procedure]. The majority of implanted devices were ICDs (17, 85%) with 5 single chamber, 4 dual chambers and 9 triple chambers ICDs. Subclavian venous approach was utilized in 9 patients. The mean duration of procedure was 60minutes. One per-procedure bleeding was described due to high venous pressure, without post-procedure hematoma. A post-procedure pocket hematoma has been experienced by one patient. The subclavian approach was used for the 2 patients. No blood transfusion was needed for these 2 cases.

Conclusion

Ticagrelor treatment at the time of heart rhythm device procedures does not seem to be associated with an increased risk of significant bleeding complications. In our study, 2 patients experienced nonsignificant bleeding complications.

Le texte complet de cet article est disponible en PDF.

Mots clés : Ticagrelor, Complications, Hématome, Pacemaker, Défibrillateur

Keywords : Ticagrelor, Complication, Hematoma, Pacemaker, ICD


Plan


© 2016  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 65 - N° 5

P. 318-321 - novembre 2016 Retour au numéro
Article précédent Article précédent
  • La réadaptation cardiaque des patients « sportifs »
  • B. Pavy, J. Darchis, E. Merle, M. Caillon
| Article suivant Article suivant
  • Prise en charge ambulatoire de l’embolie pulmonaire diagnostiquée aux urgences
  • E. Dubie, G. Pouzet, E. Bohyn, C. Meunier, A. Wuyts, S. Chateigner Coelsch, P. Lesage, C. Morvan, L. Belle, G. Vanzetto

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.