Suscribirse

Mobile-bearing insert translational and rotational kinematics in a PCL-retaining total knee arthroplasty - 23/06/09

Doi : 10.1016/j.otsr.2009.03.012 
J. Chouteau a, , b, c, d, e , J.-L. Lerat a, R. Testa a, b, c, d, B. Moyen a, b, c, d, M.-H. Fessy a, S.A. Banks e
a Department of Orthopaedics, Traumatology and Sports Medicine, Lyon-South Hospital Center, chemin du Grand Revoyet, 69495 Pierre-Bénite cedex, France 
b Lyon-1 University, 69003 Lyon, France 
c Research National Institute on Transportations and their Safety, 69675 Bron, France 
d UMR T 9406, Biomechanics and Shock Mechanics Laboratory, Lyon-South Faculty of Medicine, 69921 Oullins, France 
e Orthopaedic Biomechanics Lab, Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida, USA 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Total knee prostheses with a mobile-bearing insert were developed to provide nonconstrained joint range of motion while reducing friction forces. The purpose of this study was, based on weightbearing X-rays, to evaluate the mobility of the polyethylene tibial insert in relation to the femoral and tibial components. We studied the results of a cementless total knee arthroplasty (TKA) retaining the posterior cruciate ligament (PCL), with a mobile-bearing platform in rotation and anteroposterior translation (Innex® Anterior-Posterior Glide, Zimmer) with a mean 23-month follow-up duration after surgery.

Hypothesis

Both anterior-posterior tibiofemoral translation and intraprosthetic axial rotation occur between the mobile polyethylene insert and the tibial endplate.

Material and method

In a series of 51 primary TKA, the three-dimensional (3D) kinematics of the femoral, tibial, and mobile insert components were determined using a computerized matching system between the prosthetic 3D models and the radiographic images of the implants on three lateral follow-up weightbearing knee X-rays: films were taken in full extension, at 45° flexion, and at maximum flexion.

Results

There was a statistically significant increase in the internal rotation of the mobile tray with flexion, (up to a mean −3±3° between the femoral box and the mobile tray [p<0.0001] and up to a mean −5±7° between the tibial tray and the mobile tray [p<0.0001]). The mobile tray did not translate in relation to the tibial endplate from extension to 45° flexion (0±2mm [range: −5 to 6mm]). However, from 45° to maximum flexion, a statistically significant mean 1±2mm (range: −2 to 9mm) of anterior translation (p<0.0001) was found.

Discussion

The extent of insert mobility varies from one study to another. Some have reported relatively limited mobility stemming from a superior surface that is not highly congruent, (thus allowing anterior-posterior and mediolateral translation through gliding of the femur in contact with the insert). Other studies have reported mobile-bearing tray mobility in relation to the tibial endplate and minimal rotation at the femoral component level. In this series of PCL retaining TKA with a mobile-bearing platform, the mobile-bearing platform showed a progressive increase in internal rotation during flexion. Most of this rotational mobility occurred between the mobile platform and the tibial endplate, confirming our hypothesis. However, with flexion, the femoral component increased its mobility relatively to the platform. During flexion, an anterior-posterior translation occurred between the femoral implant and the tibial insert, and between the tibial insert and the tibial endplate, but the direction of the mobile tibial insert translation remained unpredictable with this nonconstrained implant design used.

Level of evidence: Level IV. Prospective non-controlled therapeutic study.

El texto completo de este artículo está disponible en PDF.

Keywords : Mobile-bearing, Posterior cruciate ligament retaining, Total knee arthroplasty, Kinematics


Esquema


© 2009  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 95 - N° 4

P. 254-259 - juin 2009 Regresar al número
Artículo precedente Artículo precedente
  • Total hip arthroplasty for osteoarthritis in patients aged 80 years or older: Influence of co-morbidities on final outcome
  • E. de Thomasson, I. Caux, O. Guingand, R. Terracher, C. Mazel
| Artículo siguiente Artículo siguiente
  • Total knee arthroplasty in valgus knees: Predictive preoperative parameters influencing a constrained design selection
  • J. Girard, M. Amzallag, G. Pasquier, A. Mulliez, T. Brosset, F. Gougeon, A. Duhamel, H. Migaud

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.