Abbonarsi

Subtrochanteric femoral fractures treated with the Long Gamma3® nail: A historical control case study versus Long trochanteric Gamma nail® - 06/10/15

Doi : 10.1016/j.otsr.2015.06.018 
D. Georgiannos , V. Lampridis, I. Bisbinas
 424 Military General Hospital, Peripheriaki Odos Efkarpias, PC 56429, Thessaloniki, Hellas, Greece 

Correspondence author. Tel.: +30 2310 381000; fax: +30 2313 059007.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Gamma nail was developed for the treatment of subtrochanteric hip fractures. Despite its advantages over extramedullary devices, gamma nail has been historically related to significant complications (implant breakage, femoral fractures at the tip of the nail). There is limited data to determine if the rate of these complications was minimized by using a new design of the gamma nail. Therefore we performed a case control study between the long gamma3 nail (LG3N) and the long trochanteric gamma nail (LTGN) to assess if: (1) the complication rate in the treatment of subtrochanteric fractures using the LG3N was lower than the one using the LTGN; (2) the reoperation rate was lower after using the LG3N.

Hypothesis

The complication rate after fixation of subtrochanteric fracture of the femur is lower with LG3N than with the LTGN.

Patients and methods

This study prospectively recorded the intra- and postoperative complications of 75 patients with subtrochanteric fractures treated with the LG3N and compared them with those of a historical cohort of 83 patients treated with the LTGN. The two groups were matched regarding age, gender and fracture type. Patients with open, pathological, or impending fractures were excluded.

Results

Intraoperative complications in the LG3N group were lower (4 cases, 5.3%) compared with those in the LTGN group (9 cases, 10.8%; P=0.04). The major intraoperative complication encountered with the use of LTGN was fracture of the femur in 3 cases. We encountered in total 9 postoperative complications in LG3N (12%) and 20 in group LTGN (24%). The most frequent complication in both groups was the cut out of the lag screw (3 cases in LG3N and 7 cases in LTGN group). The overall reoperation rate was higher in LTGN group (20.4% vs 10.6%; P=0.03).

Conclusion

As a result of the improvement of its mechanical characteristics, LG3N has proved a safe and efficient implant for the treatment of subtochanteric fractures. The new design seems superior to previous generation, giving promising outcomes, reduced mechanical complication rates, and reduced reoperation rate.

Level of evidence

Level III – case controlled study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Subtrochanteric fractures, Gamma3 nail, Intramedullary nailing, Complications


Mappa


© 2015  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 101 - N° 6

P. 675-680 - Ottobre 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Primary cup stability in THA with augmentation of acetabular defect. A comparison of healthy and osteoporotic bone
  • F. Amirouche, G. Solitro, S. Broviak, W. Goldstein, M. Gonzalez, R. Barmada
| Articolo seguente Articolo seguente
  • Influence of preoperative factors on the gain in flexion after total knee arthroplasty
  • G. Pasquier, B. Tillie, S. Parratte, Y. Catonné, J. Chouteau, G. Deschamps, J.-N. Argenson, M. Bercovy, J. Salleron

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.