Proposal of tremor quantification method - 26/09/15

Doi : 10.1016/j.rehab.2015.07.285 
M. Guihard, Dr ⁎ , E. Hutin, Dr, I.M. Albertsen, Dr, V. Mardale, Dr, J.M. Gracies, Prof
 Laboratoire analyse et restauration du mouvement, EA BIOTN, hôpitaux universitaires Henri-Mondor, Assistance publique–Hôpitaux de Paris, université Paris-Est Créteil (UPEC), Créteil, France 

⁎Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Resumen

Introduction

The diagnosis and the follow-up of pathological tremor (rest, essential or cerebellar) are difficult, especially in early stage [1]. This study defines tremor quantification indexes from a spectral analysis of EMG signals.

Methods

Bilateral EMG of the wrist flexors/pronators (FlPr) and extensors/supinators (ExSu) were recorded (Fe=1000Hz) in one patient (50 y) with a left side tremor clinically observed. Eight conditions were tested during 10s: at rest without any distraction (1), with cognitive distraction (2), with contralateral motor task (3), posture with the wrist pronated (4), semi-pronated (5), supinated (6), flexed elbows with proned wrist close to the thorax (7), walking (8). The EMG signal envelop is obtained by a band-pass [20;450Hz] and a low-pass (30Hz) filters. A power spectral density study (DSP) from 1.5 to 12Hz leaded to the calculation of the main frequency, the maximum DSP and the rhythmicity index (IR=area under the main frequency peak/total area) [2].

Results

The main frequency is similar in all conditions (FlPr G 5.4±0.1Hz, ExSu G 5.6±0.3Hz; FlPr D 7.2±0.3Hz, ExSu D 7.4±0.4Hz, mean±standard deviation). The maximum DSP is higher on left side independently to the task (e.g. Rest, ExSu G 42.33mV2/Hz, D 0.45mV2/Hz). The IR is also higher on left side with a reduced difference with cognitive or motor distraction (muscles averaged, tasks 4–8, G 47±13%, D 27±13%; tasks 2–3, G 49±16%, D 39±20%). The maximum DSP and the IR are higher in extensors than in flexors in each task (postures 4-7, FlPr G 38±18%, ExSu G 43±17%).

Conclusion

This method of tremor quantification, based on the spectral density analysis of EMG signals, shows invariant tremor main frequency, whereas the maximum DSP and the IR depend on the muscle. Only the IR seems to be impacted by the task (without vs. with distraction) and also could be used in the follow-up of tremor patient.

El texto completo de este artículo está disponible en PDF.

Keywords : Tremor, Rhythmicity, EMG, Power spectral density.


Esquema


© 2015  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 58 - N° S1

P. e117-e118 - septembre 2015 Regresar al número
Artículo precedente Artículo precedente
  • Kinematics in the brain: The additional value of motor performance analysis during fMRI measurements
  • L. Van Dokkum, D. Mottet, I. Laffont, A. Bonafé, N. Menjot De Champfleur, J. Froger, E. Le Bars
| Artículo siguiente Artículo siguiente
  • How to improve compliance in RA = Interest of an educational program
  • F. Elabed, F. Benlebna, B. Boumediene Zellat, L. Khensous, F. Miri, Z. Djaroud

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.