Suscribirse

Composition corporelle mesurée par impédancemétrie segmentaire (BIAS) et performance de sprint chez les rugbymen - 16/10/15

Doi : 10.1016/j.scispo.2015.08.002 
M. Guiraudou a, b, L. Maimoun e, J.-M. Dumas b, M. Julia d, I. Raingeard c, J.-F. Brun a, , b
a Inserm U1046, CNRS UMR9214, « physiologie et médecine expérimentale du cœur et du muscle », université de Montpellier, 34090 Montpellier, France 
b Équipe d’exploration métabolique (CERAMM), département de physiologie clinique, hôpital Lapeyronie, 34295 Montpellier cedex 5, France 
c Équipe d’endocrinologie, diabétologie, nutrition, hôpital Lapeyronie, CHU de Montpellier, 34295 Montpellier, France 
d Fédération de médecine du sport, hôpital Lapeyronie, CHU de Montpellier, Montpellier, France 
e Service de médecine nucléaire, hôpital Lapeyronie, CHRU de Montpellier, 391, avenue du Doyen-Giraud, 34295 Montpellier cedex 5, France 

Auteur correspondant.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 5
Iconografías 1
Vídeos 0
Otros 0

Résumé

Introduction

La bio-impédancemétrie (BIA) perd en précision chez les athlètes très minces ou très lourds à cause de limitations du modèle traditionnel qui assimile le corps à un cylindre. Ces limitations sont corrigées par un modèle plus proche de la réalité anatomique, utilisé par la BIA segmentaire.

Synthèse des faits

Nous avons testé un nouveau dispositif utilisant cette approche, le Biacorpus RX4000 (Healthnesslink, France), que nous avons validé d’abord contre la DEXA et ensuite utilisé chez une équipe de rugbymen. La validation chez 96 sujets couvrant un éventail de IMC 13–48kg/m2 a montré pour la masse grasse (MG) une concordance remarquable (r=0,988 ; erreur moyenne 0,532 [95 % intervalle de confiance, IC : −0,495 ; 1,56]) avec DEXA. La composition de chaque segment est prédite avec précision (r=0,823–0,958). Dans une équipe de 29 rugbymen (âge : 18–31ans ; indice de masse corporelle moyen : 29 [allant de 21 à 41kg/m2]), nous avons trouvé un % moyen de masse grasse de 18,46 %, la masse musculaire étant en moyenne du double de la masse grasse. Alors que ni la masse musculaire mesurée avec BIA, ni la BCM n’étaient prédictifs des mesures de performance de sprint, le temps de 10m en sprint était fortement corrélé à la masse grasse (r=0,738, p<0,01) et au pourcentage de masse grasse (r=0,750, p<0,01). De même le temps mis à effectuer le test de sprints répétés de Gacon 45-15 était corrélé à la masse grasse (r=0,783, p<0,01) et au % FM de masse grasse (r=0,693, p<0,01).

Conclusion

Ainsi, cette technique nouvelle de BIA segmentaire fournit une détermination plus précise de la masse maigre et de la masse grasse chez les sujets minces et obèses, et fournit des mesures fortement corrélées avec la performance au sprint et au test de Gacon chez les rugbymen, mettant en évidence l’effet négatif d’un excès de masse grasse sur cette performance.

El texto completo de este artículo está disponible en PDF.

Summary

Introduction

We previously reported highly significant correlations between body cell mass (BCM) measured by BIA and aerobic capacity in rugby players. However, BIA loses precision in slim or heavy athletes due to limitations of the model that are overcome with segmental BIA.

Synthesis of the facts

We tested a new device using this approach, the RX4000 Biacorpus (Healthnesslink, France), that we validated first against DEXA and then applied to a team of rugby players. Validation in 96 subjects covering a range of BMI 13–48kg/m2 showed for fat mass (MG) a remarkable agreement (r=0.988; average error 0.532 [95% confidence interval, CI: −0.495; 1.56]) with DEXA. The composition of each segment is accurately predicted (r=0.823–0.958). In a team of 29 rugby players (age: 18–31yr; mean body mass index 29 (ranging from 21–41kg/m2), we found an average % of fat mass of 18,46% and muscle mass was on the average two-fold bigger than fat mass. However, neither muscle mass nor BCM measured with BIA were predictor of measurements of sprint performance, while the time of 10m sprint was strongly correlated to fat mass (r=0.738, P<0.01) and to % fat mass (r=0.750, P<0.01) as did the time to perform Gacon's 45-15 repeated sprint test (FM r=0.783, P<0.01; % FM r=0.693, P<0.01).

Conclusion

Thus, this new segmental BIA technique provides a markedly improved determination of fat and fat free mass in lean and obese subjects and provides measurements strongly correlated with sprint and repeated test performance in rugby players, emphasizing the negative effect of excess fat mass on this performance.

El texto completo de este artículo está disponible en PDF.

Mots clés : Masse maigre, Impédancemétrie bio-électrique, Absorptiométrie biphotonique (DEXA), Impédancemétrie segmentaire

Keywords : Fat-free mass, Bioelectrical impedance analysis, Dual-energy X-ray absorptiometry, Segmental BIA


Esquema


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 30 - N° 5

P. 298-302 - octobre 2015 Regresar al número
Artículo precedente Artículo precedente
  • Relationships between power outputs measured from force-velocity test, Optojump test and Five-jump test in male shot putters
  • M. Landolsi, L. Labiadh, F. Zarrouk, P. Lacouture, Z. Tabka
| Artículo siguiente Artículo siguiente
  • Effects over one year of low-intensity endurance exercise targeted at the level of maximal lipid oxidation
  • M. Guiraudou, C. Fédou, A.-J. Romain, A. Sferlazza, E. Calas, J.-F. Brun

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.