Suscribirse

Shear wave elastography: An accurate technique to stage liver fibrosis in chronic liver diseases - 09/01/16

Doi : 10.1016/j.diii.2015.11.001 
A. Guibal a, b, , G. Renosi a, A. Rode c, J.Y. Scoazec d, O. Guillaud e, L. Chardon f, M. Munteanu g, J. Dumortier e, F. Collin b, T. Lefort a
a Service de radiologie, hôpital Édouard-Herriot, hospices civils de Lyon, 69437 Lyon, France 
b Service de radiologie, centre hospitalier de Perpignan, 20, avenue du Languedoc, 66046 Perpignan cedex 9, France 
c Service de radiologie, hôpital de la Croix-Rousse, hospices civils de Lyon, 69317 Lyon, France 
d Service d’anatomo-pathologie, hôpital Édouard-Herriot, hospices civils de Lyon, 69437 Lyon, France 
e Fédération des spécialités digestives, hôpital Édouard-Herriot, hospices civils de Lyon, 69437 Lyon cedex 03, France 
f Fédération de biochimie, hôpital Édouard-Herriot, hospices civils de Lyon, 69437 Lyon, France 
g Hepatology research unit, biopredicitive, 75007 Paris, France 

Corresponding author. Service de radiologie, centre hospitalier de Perpignan, 20, avenue du Languedoc, 66046 Perpignan cedex 9, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Objectives

The goals of this study were to assess the diagnostic accuracy of shear wave elastography (SWE) using the results of histopathological analysis as a standard of reference and compare the results of SWE and those of transient elastography (TE) to the degree of fibrosis as evaluated by histomorphometry.

Patients and methods

Adult patients who were scheduled to undergo liver biopsy were prospectively enrolled in the study. The diagnostic performances of SWE were assessed using AUROC curve analysis according to fibrosis thresholds defined by ≥F2 (significant fibrosis), ≥F3 (advanced fibrosis) and F4 (cirrhosis). Additional analyses using the Obuchowski measures for pairwise comparisons of fibrosis stages were performed. In a subgroup of 55 patients, the relationships between stiffness as measured using SWE and TE and the percentage of fibrosis were compared using Spearman's rank coefficient.

Results

Among the initially enrolled 170 patients, 148/170 (87%) had successful SWE acquisition and formed the study population. SWE sensitivity and specificity were respectively 85.1% and 82.7% (≥F2), 88.9% and 90.3% (≥F3), 93.3% and 98.3% (F4). The AUROC curves of SWE along with their 95% confidence intervals (CI) were respectively 0.904 (95%CI: 0.845–0.946) for fibrosis ≥F2; 0.958 (95%CI: 0.912–0.984) for fibrosis ≥F3 and 0.988 (95%CI: 0.955–0.999) for fibrosis=F4. The global Obuchowski measure was 0.953±0.007. In the subgroup study, a significant correlation was found between the percentage of fibrosis and stiffness as assessed by SWE (r=0.77; 95%CI: 0.63–0.86; P<0.0001) and by TE (r=0.65; 95%CI: 0.47–0.78; P<0.01).

Conclusion

SWE is accurate to assess liver fibrosis in patients with chronic liver disease.

El texto completo de este artículo está disponible en PDF.

Keywords : Elastography, Sonoelastography, Cirrhosis, Liver fibrosis, Elasticity imaging techniques

Abbreviations : SWE, TE, (w)AUROC, CI, ARFI, HBV, HCV, BMI, ROI, kPa, ICC, IQR, AST, ALT, GGT


Esquema


© 2015  Éditions françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 1

P. 91-99 - janvier 2016 Regresar al número
Artículo precedente Artículo precedente
  • Arterial splanchnic aneurysms: Presentation, treatment and outcome in 112 patients
  • R. Tétreau, H. Beji, L. Henry, P.-J. Valette, F. Pilleul
| Artículo siguiente Artículo siguiente
  • Uterine remnant: An uncommon finding after transvaginal hysterectomy
  • G. Ssi-Yan-Kai, E. Faivre, S. Prevot, X. Deffieux, J. De Laveaucoupet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.