Suscribirse

Repeated metal ion measurement in patients with bilateral metal on metal (ASR™) hip replacements - 18/03/16

Doi : 10.1016/j.otsr.2015.12.015 
A. Reito , O. Lainiala, J. Nieminen, A. Eskelinen
 Coxa Hospital for Joint Replacement, Biokatu 6b, 33520 Tampere, Finland 

Corresponding author. Tel.: +35 8408 423440.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Blood metal ion measurements have become a cornerstone in the surveillance of metal-on-metal (MoM) hip replacements. Interpretation of these levels in patients with bilateral MoM hip replacements, however, is challenging. We therefore asked (1) if there is a clinically significant change in whole blood (WB) Co or Cr levels in repeated WB assessment in patients operated on with bilateral ASR hip replacements, and (2) what proportion of patients has WB Co or Cr level below the previously established safe upper limits (SUL) (Co<5.0μg/L, Cr<7.4μg/L) in the repeated WB metal ion assessment.

Hypothesis

We hypothesized that there is a significant difference between repeated Co and Cr level measurement performed within one year±4 months interval in patients with bilateral ASR hip replacements.

Materials and methods

We identified all patients (n=139) who had received bilateral ASR hip replacements (278 hips). Patients (n=76, 152 hips) who had undergone two blood metal ion measurements within eight to sixteen months’ time interval were included in the study analysis. Study cohort included 38 patients with bilateral ASR hip resurfacings (mean age 53 years, median follow-up 4.6 years, median femoral diameter 51mm) and 38 patients with bilateral ASR XL total hip replacements (mean age 60 years, median follow-up 3.6 years, median femoral diameter 49mm).

Results

There was no significant change in Co and Cr levels between the repeated measurements in the HR cohort. Both Co and Cr were significantly higher in the THR cohort in the repeated measurement (Co: 8.3μg/L vs. 12.6μg/L, Cr: 3.15μg/L vs. 3.4μg/L, both P<0.001). WB Co and Cr levels remained below SUL and within their initial values during a mean one-year measurement interval in the majority of patients with bilateral high risk HR device. In contrast to this, 21.1% of patients with THRs had WB Co ion levels exceeding the SUL in the first measurement. WB Co values significantly increased over the measurement interval in the THR group.

Discussion

Annual blood metal ion measurement is not useful in patients with bilateral hip resurfacings who have undergone at least one preliminary screening including both metal ion measurement and cross-sectional imaging. It seems, however, to be beneficial in patients with bilateral high risk MoM THR.

Level of evidence

Level III (retrospective comparative study).

El texto completo de este artículo está disponible en PDF.

Keywords : Metal-on-metal, Hip resurfacing, Metal ion levels, Surveillance


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 2

P. 167-173 - avril 2016 Regresar al número
Artículo precedente Artículo precedente
  • Can the presence of an infection be predicted before a revision total hip arthroplasty? Preliminary study to establish an infection score
  • J.-Y. Jenny, B. Adamczewski, E. De Thomasson, J. Godet, H. Bonfait, C. Delaunay, French Hip, Knee Society (SFHG)
| Artículo siguiente Artículo siguiente
  • Effects of third fragment size and displacement on non-union of femoral shaft fractures after locking for intramedullary nailing
  • J.R. Lee, H.-J. Kim, K.-B. Lee

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.