ShearWave elastography of fetal lungs in pregnant baboons - 09/06/16

Doi : 10.1016/j.diii.2015.11.019 
E. Quarello a, b, c, , R. Lacoste d, J. Mancini e, f, S. Melot–Dusseau d, G. Gorincour c
a Department of obstetric ultrasound, hôpital Saint Joseph, 26, boulevard de Louvain, 13285 Marseille cedex 08, France 
b Institute of reproductive medicine, 6, rue Rocca, 13008 Marseille, France 
c EA 4264, CERIMED, LIIE (experimental interventional radiology laboratory), Medical school, Campus santé/Aix Marseille université, 27, boulevard Jean-Moulin, 13385 Marseille cedex 5, France 
d CNRS UPS846 primatology research center, 13790 Rousset-en-Arc, France 
e AP–HM, hôpital de la Timone, BiosTIC, department of biostatistics and information and communication technology, 13385 Marseille, France 
f Inserm, IRD, UMR912 SESSTIM, Aix-Marseille université, 13385 Marseille, France 

Corresponding author. Department of obstetric ultrasound, hôpital Saint Joseph, 26, boulevard de Louvain, 13285 Marseille cedex 08, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

The purpose of this study was to evaluate the feasibility and reproducibility of transabdominal ShearWave elastography of fetal lungs in pregnant baboons.

Materials and methods

During a 9-month period (03/2013–12/2013), two operators prospectively performed ultrasound examinations of fetal lung in pregnant baboons in a primate research center. Evaluation of fetal lungs was first performed in B mode. The ShearWave elastography mode was then activated. Three elasticity measurements were performed by each operator for each lung. Each time, the operator recorded whether the lung was distal or proximal regarding the distance to the probe. Intra- and interobserver reproducibility was assessed using intra-class correlation coefficients (ICC).

Results

Twenty-one pregnant baboons were included and ultrasound examinations were performed between 1 and 3 times on each baboon. Measurements were feasible by both operators in 100% of the cases. Intra-observer ICC for the single values of proximal and distal lungs were 0.336 (95% CI: 0.191–0.484) and 0.433 (95% CI: 0.292–0.570), respectively. Intra-observer ICC for the average values of proximal and distal lungs were 0.603 (95% CI: 0.415–0.738) and 0.697 (95% CI: 0.553–0.799), respectively. Inter-observer ICC for the single values of proximal and distal lungs were 0.654 (95% CI: 0.422–0.806) and 0.421 (95% CI: 0.113–0.654), respectively. Inter-observer ICC for the average values of proximal and distal lungs were 0.791 (95% CI: 0.593–0.893) and 0.592 (95% CI: 0.203–0.791), respectively.

Conclusion

Transabdominal ShearWave elastography of fetal lungs in pregnant baboons is feasible. However, intra- and inter-operator reproducibility is acceptable when the mean of three measurements is used. Further studies are thus needed before an objective study of lung maturity with ShearWave elastography can be carried out.

El texto completo de este artículo está disponible en PDF.

Keywords : Ultrasound, Elastography, ShearWave, Lungs, Prenatal


Esquema


© 2016  Editions françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 6

P. 605-610 - juin 2016 Regresar al número
Artículo precedente Artículo precedente
  • Applications of dual energy computed tomography in abdominal imaging
  • T. Lestra, S. Mulé, I. Millet, A. Carsin-Vu, P. Taourel, C. Hoeffel
| Artículo siguiente Artículo siguiente
  • Prevalence and clinical significance of supra- or infraclavicular drainage on preoperative lymphoscintigraphy in women with breast cancer
  • T. Tanaka, S. Sato, A. Tada, R. Inai, N. Taira, H. Doihara, S. Kanazawa

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.