Suscribirse

Application of 3D printing technology on the treatment of complex proximal humeral fractures (Neer3-part and 4-part) in old people - 26/10/16

Doi : 10.1016/j.otsr.2016.06.009 
W. You a, b, L.J. Liu a, H.X. Chen a, J.Y. Xiong a, D.M. Wang a, J.H. Huang b, J.L. Ding a, D.P. Wang b,
a Department of traumatic orthopaedics, the affiliated clinical college Shenzhen second people's hospital, Anhui medical university, 230000 Hefei, Anhui, P.R. China 
b Shenzhen digital orthopedics technology engineering laboratory, Sun Gang West road, 518035 Shenzhen, Guangdong, P.R. China 

Corresponding author. Department of traumatic orthopaedics, the affiliated clinical college Shenzhen second people's hospital, Anhui medical university, 230000 Hefei, Anhui, P.R. China. Tel.: +8613510651995.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

This study was conducted to investigate the feasibility and clinical potential of using the 3D printing technology (3DPT) versus typical strategy (thin-layer CT scan) for the treatment of complicated proximal humeral fractures (PHFs) in old people.

Methods

Sixty-six old patients age ranging from 61 to 76 years with persistent complicated PHFs were randomly assigned to two groups as per the controlled randomization table (34 cases in the test group and 32 cases in the control group). In the test group, 3DPT was applied to build the 3D facture model of a patient, according to the data acquired from the thin-layer CT scan and subsequently processed with Mimics software. This helped to confirm the diagnosis, design the individual operation plan, simulate the surgical procedures and perform the surgery as plan. In the control group, only thin-layer CT scan was applied for the design of the operation plan prior to the surgery. Here, parameters including surgery duration, blood loss volume during surgery, the number of fluoroscopy, time to union were statistically analyzed for two groups after the operation. The screw lengths designed before the surgery and measured during the surgery were compared.

Results

The 3D PHF model generated using 3DPT was able to provide the visual display and omni-directional observation of the direction and severity of the fracture dislocation, which facilitated preoperative diagnosis, operation planning and design, data measurement, preselection of internal fixator and surgical outcome simulation. According to the follow-up ranging from 12∼28 months for the 66 patients, the results showed no significant difference in time to union between the two groups (P>0.05). Apart from that, less surgery duration, less blood loss during surgery, less number of fluoroscopy can be observed compared with the control group (P<0.05).

Conclusions

In this study, 3DPT showed great clinical feasibility of the treatment of complicated PHFs. The 3D-print PHF model had the ability to clearly display the fracture and thus was useful to determine the fracture classification and the magnitude of fracture injury. It benefited surgeons to gain a better understanding of complicated PHFs, design a most suitable operation plan prior to surgery and facilitate the doctor-patient communication. This therefore enabled the reduction of intraoperative injury and the optimization of surgical outcomes.

El texto completo de este artículo está disponible en PDF.

Keywords : Proximal humeral fracture, 3D printing, Computer-aided orthopaedic surgery, Thin-layer CT scan, Old patients


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 7

P. 897-903 - novembre 2016 Regresar al número
Artículo precedente Artículo precedente
  • A comparison of double Endobutton and triple Endobutton techniques for acute acromioclavicular joint dislocation
  • D. Lu, T. Wang, H. Chen, L.-J. Sun
| Artículo siguiente Artículo siguiente
  • Subscapularis and deltoid preserving anterior approach for reverse shoulder arthroplasty
  • A. Lädermann, E.Y. Lo, A.J. Schwitzguébel, E. Yates

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.