Suscribirse

Is anterior glenoid bone block position reliably assessed by standard radiography? A cadaver study - 09/11/16

Doi : 10.1016/j.otsr.2016.08.005 
P. Clavert a, b, , G. Koch a, L. Neyton c, P. Metais d, J. Barth e, G. Walch c, L. Lafosse f
the

French Arthroscopic Society

a Institut d’anatomie normale, FMTS, faculté de médecine, 4, rue Kirschleger, 67085 Strasbourg cedex, France 
b Service de chirurgie du membre supérieur, CCOM, avenue Baumann, 67400 Illkirch, France 
c Centre orthopédique Santy, hôpital privé J.-Mermoz (Ramsay-GDS), 24, avenue Paul-Santy, 69008 Lyon, France 
d Clinique La Châtaigneraie, 63110 Beaumont, France 
e Centre ostéo-articulaire des Cèdres, parc Sud Galaxie, 5, rue des Tropiques, 38130 Échirolles, France 
f Clinique générale d’Annecy, 74000 Annecy, France 

Corresponding author. Laboratoire ICube–UMR 7357, institut d’anatomie normale, faculté de médecine, 4, rue Kirschleger, 67085 Strasbourg cedex, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Standard radiography with an antero-posterior view and Bernageau's glenoid profile view is the method most widely reported in the literature to assess coracoid bone block position and fusion.

Objective

The aim of this cadaver study was to determine whether the antero-posterior and Bernageau's radiographs provide a reliable and reproducible evaluation of the position of a coracoid bone block and its fixation screws.

Method

An isolated scapula showing no evidence of osteoarthritis or other abnormalities was used. The coracoid process was transferred to the anterior glenoid rim. Fixation was with two slightly diverging malleolar screws, chosen of different sizes for ease of identification. Computed tomography (CT) was performed as the reference imaging technique. The standard radiographs were then obtained, using fluoroscopy to accurately position the scapula for the antero-posterior and Bernageau's views. This position was defined as 0°, and radiographs were taken at angles of 5°, 10°, and 15° in all three planes. All radiographs were taken during a single session to ensure that the distance separating the tube from the scapula remained unchanged. The images were exported to OsiriX for analysis. We measured the angles formed by the screws and the glenoid surface, as well as bone block position and overhang. Finally, we used 1-mm thick disks to evaluate bone-to-bone contact.

Results

No correlations were found between values by CT and by standard radiography (both views) for the screw angles or overhang. A space1mm between the neck of the scapula and the bone block was not visible on the standard radiographs in any of the positions.

Conclusion

Standard radiography does not provide an accurate analysis of bone block position or bone-to-bone contact. CT is needed to assess bone block and screw position and bone-to-bone contact.

Level of evidence

Level III.

El texto completo de este artículo está disponible en PDF.

Keywords : Imaging, Scapula, Coracoid transfer, Position, Fusion, Bernageau


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 8S

P. S281-S285 - décembre 2016 Regresar al número
Artículo precedente Artículo precedente
  • Functional outcomes after open versus arthroscopic Latarjet procedure: A prospective comparative study
  • G. Nourissat, L. Neyton, P. Metais, P. Clavert, B. Villain, D. Haeni, G. Walch, L. Lafosse, the French Arthroscopic Society
| Artículo siguiente Artículo siguiente
  • Complications in posteromedial arthroscopic suture of the medial meniscus
  • N. Jan, B. Sonnery-Cottet, J.-M. Fayard, C. Kajetanek, M. Thaunat

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.